Installation

The AMP-8040 should be placed on a solid flat surface such as a 
table or shelf or in an audio/video equipment rack. It should be 
placed upright so that its weight rests on the unit’s four feet 
(removable).  See 

Ventilation

 for information on providing adequate 

cooling to the amplifier when placed in a cabinet.

Cabling and Wiring

Cabling Precautions

The amplifier must be o

 whenever you make changes to the 

input connections.

Never connect a source or preamplifier’s input to the inputs of 
the AMP-8040 directly.

All speaker wire connections must be made with the amplifier 
o

.

Do not allow a single strand of wire to touch the amplifier chassis 
or another connector.

External Trigger Connections

CAUTION!

Do not use a DC wall adapter. The long discharge time of the DC adapter’s filter 

capacitor will delay the turn-o

 of the amplifier.

Savant GPIO External Trigger Connection

Daisy Chaining External Triggers

Ventilation

The AMP-8040 must be provided with adequate ventilation for 
proper cooling.

When installing the AMP-8040 in a cabinet, be sure that the rear 
of the cabinet is open to adequate air to provide proper cooling. 

Be sure to leave a minimum of 3 inches clearance above and 
behind the amplifier and at least 2 inches on each side. 

If installed in a rack, active thermal management (such as rack 
fans) is recommended.

 

CAUTION!

 Do not block the ventilation holes on the sides and bottom of the 

AMP-8040.

Setting the Amplifiers Turn On Mode

Constant

 – Power state of the amplifier is 

controlled via the front panel master power 
button:
IN - Amplifier is powered ON (Sensing circuitry 
active)
OUT - Amplifier is powered OFF (Sensing 
circuitry inactive)

Audio Sense 

– Zone/Channel power state is 

controlled via the source inputs: 
The master power button on the front panel 
must be in the On position.
Zone/Channel turns on when an audio signal 
higher than -46dB is present on both L/R inputs 
for the zone.
Zone/Channel turns o

 after 5 min. when an 

audio signal lower than -46dB or no signal is 
present on both L/R inputs for the zone.  
Amplifier goes into standby mode if no signal is 
present on any zone/channel for 5 minutes.

3-24V AC/DC Voltage Trigger 

– Power state of 

the amplifier is controlled via an external trigger 
(Savant GPIO):  
The master Power button on the front panel 
must be in the On position.
Amplifier will turn on when the voltage trigger 
input receives a 3-24V signal.
Amplifier will turn OFF when the 3-24V signal is 
removed.

Protection Modes

The AMP-8040 provides three protection modes. Note that the 
AMP-8040 does not shut down in a protection mode; only the faulty 
zone/channel is disabled.

Central potential protection mode (LED indication)

The central potential protection mode is the only mode that 
activates the Protection LEDs on the front panel. This mode is more 
commonly known as the DC potential protection mode and is 
designed to protect the connected speakers from any DC voltage 
that is output from the AMP-8040.
When the central potential protection mode is activated, the LED 
for that respective channel will be turned on (Red). When a channel 
is in the central potential protection mode, other active channels will 
remain operational unless they are in a protection mode. After the 
fault is fixed, the AMP-8040 will automatically restart the disabled 
zone/channel.

Speaker short protection mode (no LED indication)

This mode will disable a zone/channel until the fault is fixed. After 
the fault is fixed, the AMP-8040 will automatically restart the 
disabled zone/channel.

Overload protection mode (no LED indication)

This mode will disable a zone/channel until the fault is fixed. After 
the fault is fixed, the AMP-8040 will automatically restart the 
disabled zone/channel.

Additional Information

Refer to the following documents located on the 

Savant Community

 

for additional information.

Relay and General Purpose Input/Output Profiles: Application Note

 for 

information on input and output triggers and GPIO input and outputs to 

Savant Controllers.

RacePoint Blueprint® Authoring Guide

 on how to configure the 

AMP-2000 into a Savant System.

AMP-8040-00  |  009-1187-02  |  15040

AMP-8040-00  |  009-1187-02  |  15040

45 Perseverance Way, Hyannis, MA 02601

Copyright © 2015 Savant Systems, LLC

2 of 2

savant.com

  |  508.683.2500

Reviews: