background image

Page 7 of 18 

 

FLAME ADJUSTMENT  

The  valve  supplied  with  the  appliance  has  a  HI/LO  knob  to  control  the  flame  height.   To  adjust  the 
flame height turn the adjustment knob.  Turning the knob in a clockwise direction sets the valve to the 
maximum  setting,  turning  the  knob  in  the  counterclockwise  direction  sets  the  valve  to  the  minimum 
setting.                                           

 

Control Knob 

Summary of Contents for TASMAN 5000

Page 1: ...ch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier c...

Page 2: ...nformation 10 Leak Testing 10 INSTALLATION Minimum Clearances 11 Pedestal Door Installation 11 Initial Firing Primary Air Adjustment 12 Altitude Adjustment 13 Field Assembled Parts 13 Lava Rock Log In...

Page 3: ...ESSURE Minimum 7 0 w c 1 74 kPa Minimum 11 w c 2 74 kPa MAXIMUM GAS INLET SUPPLY PRESSURE Maximum 13 5 w c 3 4 kPa Maximum 13 5 w c 3 4 kPa AIR SHUTTER SETTING adjustable from fully closed to fully op...

Page 4: ...Page 4 of 18 APPLIANCE DIMENSIONS TASMAN 5000 TASMAN 5000S...

Page 5: ...al Fuel Gas Code ANSI Z233 1 or the current CAN CGA B149 1 Installation Codes In the state of Massachusetts this product can only be installed by a licensed plumber or a licensed gas fitter Failure to...

Page 6: ...and to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result...

Page 7: ...HI LO knob to control the flame height To adjust the flame height turn the adjustment knob Turning the knob in a clockwise direction sets the valve to the maximum setting turning the knob in the coun...

Page 8: ...or to each use If the hose is damaged or there are signs of excessive abrasion or wear replace the hose See page 9 on how to gain access to hose assembly Use only the pressure regulator and hose assem...

Page 9: ...Then you slide the tank into place there is a round hole which the base of the LP cylinder will fit into Then you would attach the regulator hose assembly leak test see page 11 and replace the pedest...

Page 10: ...at are to be used with natural gas the appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of the gas system at test pressures...

Page 11: ...e with this installation manual UNPACKING Please check the appliance carefully for any damaged or missing components Report any problems to your dealer within 30 days of purchase MINIMUM CLEARANCES Th...

Page 12: ...ter to increase or decrease primary air see below and tighten the screw Increasing the primary air will cause the flame to appear more transparent and blue Decreasing the primary air will cause the fl...

Page 13: ...ced 4 for each additional 1000 feet 305m above sea level For the USA de rate the unit from sea level according to the gas installation code FIELD ASSEMBLED PARTS Your outdoor fireplace comes fully ass...

Page 14: ...Page 14 of 18 BURNER FLAME...

Page 15: ...rials or use components other than factory supplied RECOMMENDED SERVICE 1 Visually check the burner flame occasionally Visually inspect height and color of flames see page 21 2 Have the appliance insp...

Page 16: ...sure 1 Gas line shut off 1 Turn on shut off valves 2 Air in gas lines 2 Purge gas lines 3 Gas lines may not be connected 3 Connect all gas lines 4 Low pressure may be caused by bent line 4 Check for a...

Page 17: ...h Inca provided that the purchase was made through an authorized Inca dealer and is subject to the following conditions and limitations This factory warranty is nontransferable and may not be extended...

Page 18: ...defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligations and liability of Inca with respect to the Inca gas firep...

Reviews: