background image

TB-BA-e-1713 

 

 

The black chequered shaft segment is seated movable on a spring. By means of the 
spring, the sensor tip presses onto the test object with a defined force. This way, 
measurement errors will be avoided. 

 

 
It is recommended to perform several test measurements before the first use of the 
instrument. This way, further measurement errors will be avoided.   

10  Trouble-shooting 

 

10.1 The instrument should always be calibrated on the same base material used for 
the actual measurement, instead of the base plate included in delivery. By doing this, 
measurement accuracy will be better right from the start. 
 
10.2 The sensor will eventually be worn off. Its life will generally depend on the num-
ber of measurements taken and  also on the surface roughness of  the coating.  Re-
placement of a sensor should only be done by trained and experienced staff.  
     
10.3  The sensors of coating thickness gauges should only be replaced  by identical 
types or series. Otherwise, measurement accuracy may be  affected or the gauge 
could become damaged, in the way that it can no longer be used. 
       
       
Annotation:  
To have a look at the CE Declaration of Conformity, please click onto the following 
link: 

https://www.kern-sohn.com/shop/de/DOWNLOADS/

 

 
 
 

Summary of Contents for TB

Page 1: ... 72336 Balingen E Mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Digital Coating Thickness Gauge SAUTER TB Version 1 3 08 2017 GB TB BA e 1713 PROFESSIONAL MEASURING ...

Page 2: ...nal range If you have any queries wishes or helpful suggestions do not hesitate to call our service number Models TB 1000 0 1 F TB 1000 0 1 N TB 1000 0 1 FN TB 2000 0 1F Summarize 1 Features 3 2 Specifications 3 3 Front panel description 4 4 Measuring Procedure 5 5 Offset Accur 5 6 Calibration Adjustment 5 7 Batteriewechsel 6 8 Adjustment foils 6 9 Correct handling at coating thickness measurement...

Page 3: ...cs porcelain enamel copper zinc aluminium chrome lacquer layers galva nised or phosphorescent coatings alloy etc These layers should be located on magnetic metals e g steel iron nickel etc In N mode the coating thickness of nonmagnetic coatings can be measured which is located on nonmagnetic metals It is used to measure anodizing varnish paint enamel plastic coatings powder coatings etc These laye...

Page 4: ...s valid within 50 μm around the Off Set Accur point Note All tolerances are valid after the adjustment procedure Smallest measuring surface 6mm Power supply 4x1 5 AA batteries included in standard delivery Operating conditions Temperatures 0 up to 50 C Humidity 80 Dimensions 161 x 69 x 32 mm Weight about 260 g including batteries Scope of delivery Transport case Instruction manual Instrument and s...

Page 5: ... key operation 5 Offset Accur With this instrument you have got the possibility to improve the measurement result essentially by using the OFFSET Accur function Therefore it is necessary to cali brate the gauge with a reference coating in the typically measured range This kind of fine adjustment can be also done with the calibration foils included in delivery Ide ally this adjustment should be don...

Page 6: ...p 6 4 has to be repeated until the measurement accuracy is achieved 7 Batteriewechsel 7 1 If the battery symbol appears on the display of if the battery voltage is less than 4 8V batteries should be replaced 7 2 For this battery cover 3 8 has to be removed and batteries must be taken off 7 3 Batteries 4x1 5V AA have to be installed correctly into the case 7 4 If the instrument is not in use for an...

Page 7: ...ase plate included in delivery By doing this measurement accuracy will be better right from the start 10 2 The sensor will eventually be worn off Its life will generally depend on the num ber of measurements taken and also on the surface roughness of the coating Re placement of a sensor should only be done by trained and experienced staff 10 3 The sensors of coating thickness gauges should only be...