sauter FK Tensio Instruction Manual Download Page 4

 

Sauter GmbH

 

Tieringerstr. 11-15 
D-72336 Balingen 
E-Mail: [email protected]

 

Tel:  +49-[0]7433- 9976-174 
Fax: +49-[0]7433-9976-285 
Internet: www. sauter.eu 

 

 

Instruction Manual 

FK Tensio 

 

FK_T-BA-e-1110 

 

They are not suitable for hanging from a mechanical hook, 
e.g. a crane hook. 
 
9.5.1 Observe the information in the operating instructions 
please read the operating instructions carefully before 
erecting 
and commissioning, even if you already have experience 
with SAUTER instruments. 
 
9.5.2 Staff training 
The device may only be operated and looked after by 
trained members of staff.

 

 
 

 

Summary of Contents for FK Tensio

Page 1: ...cell is inside the housing Table of contents 1 Included in delivery 2 Working conditions 3 Electrical power supply 4 Technical data 5 Operation 6 Backside fixing on a test stand 7 Adjusting procedure 8 Declaration of conformity 1 Included in delivery SAUTER FK Power cable Standard attachments as shown below Terms Track continuous measurement Peak Capture of the maximum value The measuring device o...

Page 2: ...t unit N kg lb ou ZERO Zeros the measuring result Tara function Cleans the peak value in Peak mode c Display Return When the instrument itself is turned that the head faces down the display returns automatically d Measurement Track Modus Display 1 shows the continuous force in a defined direction 3 To zero the display press ZERO e Peak Hold Function Peak Mode Please press MAX 6 Backside Fixture to...

Page 3: ...Structural alterations may not be made to the instrument This can lead to incorrect measuring results faults concerning safety regulations as well as to destruction of the instrument The instrument may only be used in compliance with the described guidelines Varying areas of application planned use must be approved by SAUTER in writing 9 3 Guarantee The guarantee is not valid following non observa...

Page 4: ...110 4 They are not suitable for hanging from a mechanical hook e g a crane hook 9 5 1 Observe the information in the operating instructions please read the operating instructions carefully before erecting and commissioning even if you already have experience with SAUTER instruments 9 5 2 Staff training The device may only be operated and looked after by trained members of staff ...

Reviews: