To browse through the stored values, please use the 
▲ or ▼ keys. (The values will be shown in the upper 
display segment) 

 

 

By pressing the MEMORY key, the average value of 
the stored peak values can be shown (in the upper 
display segment) 

 

 

To delete every stored value, press the

▼-key in the 

AVERAGE-Mode 

 
 

6. 

Configuration of RS 232 

 

SUB-D 9pm 

 

Pin 

Signal 

Illustration 

TxD 

Output signal  

RxD 

Input signal 

GND 

Ground 

+1.6 to + 2 V 

Over upper limit 

+1.6 to + 2 V 

Lower than lower limit 

+1.6 to + 2 V 

OK  

 

6.1 Output Protocol 

 
RS-232 Parameter 
Baud rate:           9600 
Data-Bit:              8 
Parity:                 none 
Stop-Bit:             1 
 
The measured value is requested by the PC by the ASCII 
Sign “9”. 
 
The measured value that comes from the instrument has 
this format:  
 
e.g.        0011.70                means   -11,70 Newton, if 
Newton is the selected unit        
                ||-----| 
                |     |____>          the other 6 places describe the 
measured value as ASCII-Signs 
                |_______>          the first place describes the 
direction of the force (0 = minus = Pressure;  
     1 = plus = Tension) 
 
or:    1021.15   means  +21,15 N  (Tension) 
 

 
 
7.      Warning 

 
Intended use 
 

The instrument you have acquired serves to determine the 
measuring  value  of  the  material  to  be  measured.  It  is 
intended to be used as a “non-automatic“  instrument, i.e. 
the  material  to  be  measured  is  manually  and  carefully 
attached  at  the  instrument.  The  measuring  value  can  be 
read off after a stable measuring value has been obtained. 
 
Inappropriate use 
 
Do  not  use  the  instrument  for  medical  measurements.  In 
the case that small quantities are removed or added to the 
material  to  be  measured,  incorrect  measuring  results  can 
be  displayed  due  to  the  “stability compensation“  inside  of 
the instrument. (Example: Slow draining off of liquid from a 
container suspended from the instrument). Do not attach a 
continuous  load.  This  can  damage  the  measuring  unit  as 
well as the parts, relevant to safety. 
Prevent  jolts,  torsion  and  oscillation  (e.g.  by  appending 
slopingly)  of  all  kinds.  Be  sure  to  prevent  overloading  the 
instrument  in  excess  of  the  stated  maximum  load  (max.), 
minus  any  tare  weight  that  may  possibly  exist.  This  could 
damage the instrument (risk of breakage). 
Important: 
• Always make sure that there are no people or materials 
below the load that could be injured or damaged! 
• The instrument is not suitable for measuring people. Do 
not use as baby scales! 
• The instrument does not comply with the medical product 
law (MPG). 
Never  operate  the  instrument in hazardous  locations.  The 
series  design  is  not  explosion-proof.  Structural  alterations 
may  not  be  practised  to  the  instrument.  This  can  lead  to 
incorrect  measuring  results,  faults  concerning  safety 
regulations as well as to destruction of the instrument. The 
instrument  may  only  be  used  in  compliance  with  the 
described guidelines. Varying areas of application/ 
planned use must be approved by SAUTER in writing. 
 
 Guarantee 
 
The guarantee is not valid following 
• non-observation of our guidelines in the operating  
  instructions 
• alteration to or opening of the device 
• mechanical damage and damage caused by media,  
  liquids 
• natural wear and tear 
• inappropriate erection or electric installation 
• overloading of the measurement equipment 
 
 
 
 
 
Monitoring the test substances 
 
The metrology features of the instrument and any possible 
available adjusting weight must be checked at regular  

Summary of Contents for FH-M

Page 1: ...ER FH incl rechargeable battery Carrying Case Charger 5 pcs M3x 8 screws Important annotation By pressing the RESET key on the right side of housing see illustration on the left individual settings and memorised values can be re set or erased in example for a new start of the instrument after an operating error Data in mm Length of cable between display and sensor 2500 mm Measurement Terms Track c...

Page 2: ...or ON press 1 sec UNIT Press short Select unit N kg or lb Press for 2 sec Display return ZERO Three functions Zeros the measuring result Tara function Cleans the peak value in Peak mode Saves a setting in SET mode SET 1 x Press Upper Limit HidT Hi Lt To change press or see section High Low Limit function 1 x Press Lower Limit LodT To change press or see section High Low Limit function 1 x Press Mi...

Page 3: ...her limit This function allows efficient testing of OK NOT OK measurements of similar or identical testing objects A lower and an upper limit value can be defined The instrument compares the individual measuring results with these limit values and shows the OK or NOT OK result by green or red light diode and by sound To set these limit values please see the SET Menu in section Operating keys Measu...

Page 4: ...mall quantities are removed or added to the material to be measured incorrect measuring results can be displayed due to the stability compensation inside of the instrument Example Slow draining off of liquid from a container suspended from the instrument Do not attach a continuous load This can damage the measuring unit as well as the parts relevant to safety Prevent jolts torsion and oscillation ...

Page 5: ...ment over the maximum permitted weight Danger of breaking Always make sure that there are no living beings or materials below the load that could be injured or damaged The hanging electronic instruments from the SAUTER instrument are only suitable for hand held use or use in a test stand They are not suitable for hanging from a mechanical hook e g a crane hook Observe the information in the operat...

Page 6: ... XXX N is shown a Back to the normal mode If you are in the operation mode again the instrument has to be shut off Start again with 1 Eventually pressing the buttons faster 4 Select the instrument type Press The correspondi ng value to the instr appears in the display 5 Save instrument type Press SET 6 Enter the adjustment sequence Press MEMORY The upper red light is on 7 Choose the adjustment wei...

Reviews: