WATER HEATERS

THESE ARE CAT II2H3+ APPLIANCE

01773 828100

I N   W A R R A N T Y

T E C H N I C A L   H E L P L I N E

01773 828400

Summary of Contents for OPALIS 5

Page 1: ...1 WATER HEATERS THESE ARE CAT II2H3 APPLIANCE 01773 828100 I N W A R R A N T Y T E C H N I C A L H E L P L I N E 01773 828400...

Page 2: ...SER SECTION Introduction Page 3 Commissioning Lighting OPALIS 6 9 Commissioning Lighting OPALIS 5 10 Adjustments 11 Draining 15 Mandatory warning notice for CEE countries WARNING this appliance was de...

Page 3: ...he following versions normal pressure without taps normal pressure with taps These instructions describe how to install and use Saunier Duval appliances It is important to pay attention to the warning...

Page 4: ...Gas Usable gases TYPE pressure category OPALIS 5 fixed normal II2H3 G20 AAS This appliance is of the II2H3 Gas Category for use with Natural gas G 20 only This appliance is of the II2H3 Gas Category...

Page 5: ...aximum water pressure 1 pw bar 150 lb in2 Nominal rated heat input Q kW 39895 Btu h Temperature rise C Fresh air flow rate m3 h Natural G20 Appliance inlet pressure mbar Base pilot injector mm Vent pi...

Page 6: ...t 2 user control 3 flame supervision device 4 temperature selector Shy 094a Diagram 2 2 OPALIS 5 A2 deflector A3 heat exchanger A4 burner B gas mechanism C water mechanism E1 thermocouple E3 atmospher...

Page 7: ...is the law that all gas appliances are installed by com petent persons in accordance with the above regulations Failure to install appliances correctly could lead to prosecution It is in your own inte...

Page 8: ...heater to the wall fixing plate and measure the distance between the wall and the back of the heater This will indicate the lenght of hook required Remove the heater Drill a 6 5 mm hole in the wall an...

Page 9: ...line up with the mark b on the casing see diagram 6 1 Fully depress and then release centre button c the button will remain semi depressed see diagram 6 2 Press piezo igniter button D see diagram 5 I...

Page 10: ...t up or after long stoppage Turncontrollever 2 diagram 7 toalignredflame a with mark b on front panel diagram 8 1 OPALIS 5 5 3 2 4 6 D 1 Des 060 Description 1 Pilot tube 2 Control knob 3 Temperature s...

Page 11: ...agram 4 refer to TECHNICAL DATA for the correct inlet pressure Slow ignition The servo gas device ensures automatic adjustment of slow ignition Hot water temperature adjustment These appliances are fi...

Page 12: ...consistsofatubefixedontotheleftside of the combustion chamber The other end rests on a cradle integral with the stirrup fixed on the burner bracket If the heat exchanger becomes blocked the path offer...

Page 13: ...ard water area and a drop in water flow rate is noticed and or noise occurs the heat exchanger may need descaling Proceed as follows shut off water supply remove heat exchanger and fill with a 15 inhi...

Page 14: ...follows shut off water supply remove heat exchanger and fill with a 15 in hibited acid solution leave to act for 10 to 15 minutes then rinse thor oughly If necessary repeat operation Cleaning of pilot...

Page 15: ...modify the latter without prior notice The technical information contained in our documents are given for guidance only and are without liability DRAINING If there is a risk of frost it is essential t...

Page 16: ...16 104560 B 07 96...