Saunacore Mercuri Operating Instructions Download Page 3

8

www.saunacore.com

Mercuri Digital Control

SAUNACORE 

Figure 10

Coil

Electronic Control 

(rear view)

1 Amp

240 V

Fuse

(INLINE)

H1

L1

L2

H2

Temperature Plug

Temperature

 

Sensor 

in sauna

(over stove, ceiling
height)

Control

Ground

H.L.

Heater

Conduit 
or BX

Ground

Ground

Conduit 
or BX

L1

L2

L3

Coil

HEATER

Conduit 
or BX

Ground

L1

L2

L3

Mecuri Digital Control

(240v/208v) 1 or 3 Phase 50 Amps and over)

L1

L2

L3

Breaker  Panel

Ground

L2

L3

L1

L1

L2

L3

(Main Power Supply)

Mercuri control must be installed outside of the sauna room, into a 3 gang masonry
electrical box.  When a magnetic contactor is used, it also must be installed into an
appropriate metal electrical enclosure box outside of the sauna.

For supply connections, use suitable AWG wires suitable for at least 90 C (190 F).
(Use copper wire only). - Ground wire must be insulated.

o

o

CAUTION:  THE MANUAL RESET LIMIT SHALL BE WIRED IN THE CIRCUIT.

(applies to Canadian application)