background image

5

brilliance

 

jubilee

•  Do not use the product to clean stairs.
•  Burns can occur from touching hot 

parts, hot water or steam. Use caution 

when draining the appliance after 

use as there may be hot water in the 

appliance.

•  Do not attempt to change the 

attachments while the appliance 

is emitting steam. Use only 

manufacturer’s recommended 

accessories.

•  Do not leave the appliance unattended 

when it is connected to a power 

supply or an electrical outlet. Always 

disconnect the plug (even when it will 

be unattended for a short period of 

time).

•  Do not clean over floor electrical 

outlets. 

•  Never attempt to steam clean clothes 

which are still being worn.

•  Ensure that the appliance does not 

operate on an empty tank.

•  Do not apply steam directly to very 

cold glass surfaces.

•  Only water should be used in this 

appliance. Use distilled/purified water if 

the tap water in your area is very hard.

•  Damage caused by improper use of 

steam on objects, materials, persons 

or animals or by not observing the 

instructions in this manual will void 

warranty.

•  Always store the appliance indoors in a 

cool and dry place.

•  Do not add cleaning solutions, scented 

perfumes oils or any other chemicals 

to the appliance, as cleaning agents 

may damage the appliance or make 

it unsafe for use. Only use clean tap 

water to fill the water tank.

•  Do not use the appliance if there 

are any blockages. Switch off the 

appliance immediately and wait for 

it to cool down before carrying out 

any maintenance tasks or clearing a 

blockage. 

•  Do not insert any object in the various 

openings of the appliance. 

•  The nozzle, hose and the attachments 

will become hot during use. To avoid 

injuries, do not touch the nozzle while 

using this appliance.

•  This appliance must be grounded. If 

it should malfunction or breakdown, 

grounding provides a path of least 

resistance for the electric current to 

flow, this will reduce and prevent the 

risk of electric shock. This appliance 

is equipped with a cord having an 

equipment-grounding conductor 

and grounding plug. The plug must 

be inserted into an appropriate 

outlet that is properly installed and 

grounded in accordance with all local 

codes and ordinances.

Grounding Instructions

Summary of Contents for Brilliance Jubilee SJ-200

Page 1: ...User Manual brilliance jubilee SJ 200...

Page 2: ...2 brilliance jubilee...

Page 3: ...icient and eco friendly cleaning using the natural principle of dry steam Before operating your Sauber Brilliance Jubilee please read this instruction manual carefully and keep for future reference Ap...

Page 4: ...maged or defective it must be replaced by the manufacturer its service agent or by a qualified profesional in order to avoid a hazard Do not unplug by pulling on the power cord To unplug grasp the plu...

Page 5: ...instructions in this manual will void warranty Always store the appliance indoors in a cool and dry place Do not add cleaning solutions scented perfumes oils or any other chemicals to the appliance a...

Page 6: ...6 brilliance jubilee B A C E G F D H L M N J K I P Q B D C M J L K Display Accessories Hose A B C D E F G H I O...

Page 7: ...sh protection plate L Diamond shaped brush M High pressure steam nozzles N Special cleaning brushes O Filling bottle P Window Wiper and Brush Q Cleaning Clothes A Water shortage no heating B Steam lev...

Page 8: ...h diamond shaped brush and window wiper can be connected by following the same procedure 2 4 1 3 Assembly Remove the cable and plug the cable into the power socket Close the cable compartment Remove t...

Page 9: ...p E will turn on Wait until the steamer has reached Max tank pressure no heating G Before cleaning remove condensed water and warm up the hose by letting off steam for 15 seconds Press the switches on...

Page 10: ...g the ON OFF button F the orange light will turn off then unplug the unit from the mains power supply The patented tank closure filler cap A can only be unscrewed when the pressure in the boiler is be...

Page 11: ...boiler is heated before commencing use Low steam in the boiler heating up E The water in the boiler is still cold and heating up Wait until the water in the boiler is heated before commencing use Max...

Page 12: ...the brush clamps of the diamond shaped brush L Attach the cleaning cloth on all four brush clamps Let the brush glide without pressing on the floor Steam level 1 J Cleaning tiled floors Carpet cleanin...

Page 13: ...ray a short strong steam jet onto the stain steam level 2 Protect your fingers behind the cloth If needed repeat the process to remove stubborn stains Never treat a stain by aiming directly from above...

Page 14: ...wiper on the squeegee side and wipe the window dry from the top to the bottom Wipe away any residual dirty water with a cloth 3 Connect the window wiper P with the connector to the hose Set the wiper...

Page 15: ...en the drain cap Ensure that the water is not hot Rinse with clear water until no limescale flows out from the boiler Overtime limescale residues can deposit in the boiler The patented system of the s...

Page 16: ...ere is no more pressure in the tank the red indicator will be in the downward position and the cap can be opened In case of doubt contact Sauber Customer Service 1 Ensure the tank is empty and there i...

Page 17: ...ox steel Patented self decalcifying system Product Name Product Code Floor tool assembly 31110222 Cloth pad 31400146 Square brush 31151780 High pressure nozzle 31151781 Tool kit 31600041 Plastic bottl...

Page 18: ...ALSO AVAILABLE 5 YEAR P REMIU M W A R R A N T Y 5 YEAR P REMIU M W A R R A N T Y 18 brilliance jubilee...

Page 19: ...For a complete healthy home 5 YEAR P REMIU M W A R R A N T Y 5 YEAR P REMIU M W A R R A N T Y ALSO AVAILABLE 19 brilliance jubilee...

Page 20: ...Building 2 Brandon Business Park 530 Springvale Road Glen Waverley Vic 3150 or on 1800 728 237 Monday Friday 9am 5pm EST The decision to repair or replace the cleaner is at the sole discretion of Saub...

Reviews: