2. WIRING DIAGRAM 

2-1. PUC48R

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

Summary of Contents for PUC48R

Page 1: ...Commercial Refrigerator Service Manual SALAD SANDWICH PREP TABLE PUC48R Please read this manual completely before attempting to install or operate this equipment...

Page 2: ...1 COMPRESSOR 4 2 COMPRESSOR RELAY 4 3 CONDENSER DRYER 4 4 CAPACITOR 4 5 EVAPORATOR FAN MOTOR 4 6 CONDENSER FAN MOTOR 4 7 EVAPORATOR DEFROST HEATER 4 8 LAMP 4 9 THERMOSTAT 5 ELECTRONIC CONTROLLER INST...

Page 3: ...1 FEATURE CHART 1 1 OUTSIDE DRAWING OF PUC48R...

Page 4: ...2 WIRING DIAGRAM 2 1 PUC48R...

Page 5: ...3 PARTS DETAILS 3 1 BOTTOM PANEL THERMOSTAT MAIN SWITCH...

Page 6: ...3 2 REFRIGERATION COMPARTMENT CYCLE ASSEMBLY CONDENSER FILTER DRIER CONDENSER FAN MOTOR WATER PAN COMPRESSOR...

Page 7: ...DRAIN PAN CONDENSER FAN MOTOR ASSEMBLY FAN COVER CONDENSER FAN MOTOR BLADE CONDENSER FAN MOTOR...

Page 8: ...3 3 DOOR GASKET Magnetic gasket can be replaced without any tools...

Page 9: ...R 33 4 2 COMPRESSOR RELAY PUC48R Voltage 115V 60Hz Relay Model X 4 3 CONDENSER DRYER MODEL PUC48R Refrigerant R 404A Spec XH 9 25g Part code GN1410TN 14 4 4 CAPACITOR MODEL PUC48R Voltage 115V 60Hz Ru...

Page 10: ...60Hz Motor Model BD03 04 C06 Part code 54F 09 4 7 EVAPORATOR DEFROST HEATER MODEL PU48R Voltage 115V 60Hz Spec Part code 4 8 LAMP MODEL PUC48R Voltage 115V 60Hz Spec Part code 4 9 MAIN PCB MODEL PUC4...

Page 11: ...110 SET 230 Yes 110 230 10 50 5 Ot Thermostat probe calibration 12 12 120 120 0 32 1 1 6 P2P Evaporator probe presence n not pres y pres Y Y Y 7 OE Evaporator probe calibration 12 12 120 120 Yes 0 32...

Page 12: ...EF Yes Set Set set 22 dAd MAX display delay after defrost 0 255min Yes 30 30 30 25 dAF Defrost delay after fast freezing 0 23h n 50 Yes 0 0 0 0 30 Alc Temperature Alarm configuration RE related to set...

Page 13: ...tivation of pressure 0 15 Yes 15 15 15 39 odc Compressor status with open door no Fan normal CPr comp OFF F C Compr OFF fan OFF Yes no no no 40 Pbc Kind of probe Ptc ntc ntc Ptc ntc ntc 41 dp1 Room pr...

Page 14: ...last alarm occurrence in programming mode it browses the parameter codes or increases the display value To view the last alarm occurrence in programming mode it browses the parameter codes or decreas...

Page 15: ...for more than 2 seconds and a manual defrost will start 2 4 HOW TO LOCK THE KEYBOARD 1 Hold the and keys for more than 3s 2 The POF message will be displayed and the keyboard will be locked At this po...

Page 16: ...6 REPLACEMENT OF MAIN COMPONENTS 6 1 BOTTOM PANEL PARTS 6 1 1 UNSCREW BOTH SIDES OF THE BOTTOM PANEL 6 1 2 PULL THE BOTTOM PANEL OUT...

Page 17: ...6 1 3 UNSCREW THE JUNCTION BOX 6 2 DOOR CHANGING 6 2 1 UNSCREW THE BOTTOM HINGE...

Page 18: ...6 2 2 PULL DOWN DOOR 6 2 3 CHANGE THE DOOR HINGE A PUT THE DOOR ON A FLAT LEVEL B UNSCREW THE HINGE...

Page 19: ...HE SPRING HINGE 6 3 REFRIGERATION COMPARTMENT PARTS 6 3 1 BEFORE OPENING THE REFRIGERATION COMPARTMENT PLEASE TAKE ALL THE PANS OUT AND TAKE THE PAN SUPPORT OFF 6 3 2 TAKE THE SHELVES K SHAPE CLIPS AN...

Page 20: ...6 3 3 UNSCREW THE EVAPORATOR COVER 6 3 4 TAKE OFF THE EVAPORATOR COVER 6 3 5 CHANGE EVAPORATOR AND WATER PAN A UNSCREW THE EVAPORATOR...

Page 21: ...VAPORATOR PIPE AND DISCONNECT THE WIRE TO THE SENSOR C UNSCREW THE SCREWS FOUND AT THE TOP OF THE EVAPORATOR AND DISCONNECT IT REPLACE THE EVAPORATOR AND REATTACH THE PIPE AND CONNECT THE SENSOR WIRES...

Page 22: ...6 4 2 UNSCREW THE UNIT BOARD YOU CAN PULL THE UNIT BOARD OUT FOR ANY REPAIRS OR CLEANING...

Page 23: ...TION BE CAREFUL OF ELECTRIC SHOCK CAUTION MAKE SURE THE POWER SUPPLY IS CUT OFF BEFORE ANY SERVICE IS PERFORMED CAUTION CONDENSING UNIT MAY BE VERY HOT BE SURE IT IS COOL BEFORE ANY SERVICE IS PERFORM...