background image

INSTALLATION (continued) 

INSTALLING THE GAS GRIDDLE 
Refer to the nameplate. Verify the fuel type and pressure, which must

 

match the nameplate specifications. Connecting the griddle to the

 

wrong fuel type and/or pressure will compromise the safety and/or

 

performance of the appliance. 
BE SURE TO MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLE 
SURFACES. 

The  griddle  must  be  placed  in  its  final  operational  position  and  leveled

 

front-to-back  and  side-to-side, with  a  spirit  level, prior  to beginning  the

 

gas piping installation. Re-check the level of the unit at the conclusion

 

of 

the gas piping installation. 
Each gas griddle is supplied with a separate gas pressure regulator,

 

which must be installed on the manifold pipe protruding from the rear

 

of 

the griddle. Ensure that the regulator is installed such that the flow

 

arrow 

stamped on the body of the regulator points toward the griddle.

 

Failure to 

properly install the supplied regulator will result in an extremely 
hazardous condition. 
A moisture trap (drip leg) consisting of a tee, 4” nipple pointing down,

 

and cap must be installed upstream of the gas pressure regulator. 
A manual gas shut-off valve may be required by local codes and is,

 

in 

any case, strongly recommended. The shut-off valve must be

 

installed between the gas supply piping and the gas pressure

 

regulator. 

Shut-off valves, moisture trap and all associated piping must be

 

supplied by the gas piping installer. 

 

It is the responsibility of the gas piping installer to

  

identify the code requirement for a shut-off valve. 

 

DANGER: 
FIRE AND EXPLOSION

 

HAZARD 
NEVER  use  an  open  flame  to

 

check  for  gas  leaks.  Fire  and

 

explosion may result. 

IMPORTANT: 
All pipe joints must be checked

 

for leaks before lighting. Leak

 

checks should be performed

 

with a soap and water solution. 

WARNING: 
FIRE HAZARD 
This griddle is supplied with a

 

gas pressure regulator. 
Failure to properly install the

 

supplied regulator will result in

 

an extremely hazardous

 

condition. 
Flow arrow stamped on body

 

of regulator must point toward

 

the griddle. 
Vent hole must point UP. 

IMPORTANT: 
Verify fuel gas type. If the

 

available fuel does not match

 

the nameplate specification,

 

exchange the griddle for the

 

correct type. 

IMPORTANT: 
The appliance and its 

individual manual shutoff valve

 

must be disconnected from

 

supply system piping during

 

any pressure testing of that

 

system at pressures in excess

 

of 1/2 p.s.i. (3.5 kPa). 
Also, the appliance must be

 

isolated from the gas supply

 

piping system by closing its

 

individual manual shutoff valve

 

during any pressure testing of

 

the gas supply piping at test

 

pressures equal to or less than

 

1/2 p.s.i. (3.5 kPa). 

 

IN

S

T

A

L

L

A

T

IO

N

 (C

o

n

tin

u

ed

Page 7 

Summary of Contents for ESG-24

Page 1: ...Instructions to be followed in the event the user smells gas fumes must be posted in a prominent location in the installed kitchen area The information shall be obtained from a local gas supplier WAR...

Page 2: ...f this price list does not constitute an agree ment or offer to sell product to the possessor Prices are subject to change without notice Prices do not include sales tax All prices are in U S dollars...

Page 3: ...nspection Manufactuer cannot assume liability for damage or loss incurred in transit We will however at your request supply you with the necessary documents to support your claim TABLE OF CONTENTS WAR...

Page 4: ...3 FEATURES OPERATING CONTROLS ADJUSTABLE LEG BURNER ASSEMBLIES PILOT LIGHTS PILOT ADJUSTMENT CONTROL VALVE TYPICAL Fig 1 Medium Duty Gas Griddle Features Operating Controls FEATURES AND OPERATING CONT...

Page 5: ...the supplied 4 legs properly installed Do not operate this appliance if the smell of gas is present Turn off all gas supply valves and move to a remote location to call your manufacturer for service...

Page 6: ...NOTICE Manufacturer s warranty on this griddle is in effect only when the griddle is installed in accordance with these instructions and local codes and ordinances or in the absence of local codes th...

Page 7: ...e gas supply line used to connect the griddle to the gas supply system must be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supply piping must be inside 3 4 di...

Page 8: ...e shut off valve must be installed between the gas supply piping and the gas pressure regulator Shut off valves moisture trap and all associated piping must be supplied by the gas piping installer It...

Page 9: ...bs before returning the unit to service ADJUST BURNER FLAME Remove all burner control knobs then remove the front panel Turn an individual burner on Loosen the locking screw on the shutter Turn the sh...

Page 10: ...o smell near floor level because some gas is heavier than air and will settle to the floor For initial startup and any time the gas supply has been shut off it may take several minutes to light the pi...

Page 11: ...s from OFF to ON The right knob controls the front burner The left knob controls the rear burner Light the burner by turning the control knob to the ON position until fire forms completely around the...

Page 12: ...thoroughly cleaned Using a scraper remove all grease and food waste from the grease trough by pushing it down the waste hole and into the grease tray 6 After scraping all cooking waste from grease tro...

Page 13: ...rior surfaces dry with a soft clean cloth Allow burners to air dry so that interior passages are completely free of water Examine burners to be sure the air shutters are in their proper position Reins...

Page 14: ...internal component Contact manufacturer for repairs Pilot will not light Gas supply off Check main unit gas valves Air in lines Turn pilot valve on Attempt to light pilot every 15 sec Pilot valve not...

Page 15: ...information available if calling for service RESTAURANT______________________________ LOCATION _______________ INSTALLATION DATE _________________________ TECHNICIAN______________ SERVICE COMPANY ____...

Page 16: ...Page 15...

Page 17: ...Page 16...

Reviews: