4. CaIibration
1. When the power is off, press and hold
key till LCD shows a value, wait until
the value stabilizes.
2. Press
key again , LCD reads “
”, later LCD will show another value “xxxx”
3. According to the value shown on LCD (EX:5000), place the same value calibration
weight (5000 g) on the platform.
Press
key again, LCD will show “CAL” then “PASS”.
4. Remove the calibration weight from the platform and turn off the power.
5 .Warranty
We offer one year limited Warranty if the scale is under proper use.
Under the following conditions, we will charge components cost even though the scale is
within warranty period:
1. Damage/defective caused by misuse and negligence.
2. Damage/defective due to repair by unauthorized persons.
3. Damage/defective due to improper environment such as damp, crush, corrosion etc.
4. Damage/defective due to the factors of force majeure (fi re, earthquake etc.).