SATO SK-180GT Instruction Manual Download Page 8

 

 

 

When measuring outdoors in the sun, make sure that the entire globe is exposed to direct sunlight. 

Do not let obstacles or clothing block the direct sunlight. 

 

Switching WBGT measurement environment 

The formula for calculating the heat index (WBGT) differs between outdoor and indoor measurement 

environments. Switch the instrument's outdoor / indoor settings according to the measurement 

environment. 

* The factory default setting is 

“Outdoor”. 

 

How to set the WBGT measurement environment 

Press the SELECT key in the measurement mode to choose the WBGT measurement environment 

setting. 

Measurement environment 

      Environment Mark 

          Usage 

Outdoor 

  mark is not displayed 

When used outdoor (place in the sun) 

Indoor 

  mark is displayed 

When used indoor or outdoor at the place 

not in the sun 

 

Keylock function 

To prevent the incorrect operation, the keylock function is equipped. 

 

. How to activate the keylock function 

  Press the MENU and SELECT key simultaneously in the measurement mode for longer than 2 

seconds. The keylock mark lights up and the key is locked. 

 

To cancel the keylock

 

function, repeat 

. The keylock mark turns off and the keylock

 

function is 

canceled.

 

 

 

 

Various functions settings 

How to set the 

“Heat stress index” and alarm 

  Turn on the power. Press the MENU and SELECT key simultaneously for longer than 2 seconds to 

enter the setting mode. 

  Press the MENU key to switch the setting mode as shown below. 

 

 

 

Summary of Contents for SK-180GT

Page 1: ...INSTRUCTION MANUAL No 8313 00 Heat Stress Monitor Model SK 180GT R 12...

Page 2: ...daptability to hot environment etc WARNING Never use this instrument in an atmosphere exposed to inflammable gases as it may explode If there is anything you are not clear about this instrument please...

Page 3: ...l suffocation around the neck Do not swing the instrument with the neck strap key ring or carabiner attached There is a risk of unexpected accidents or damage For repairs or calibrations contact us or...

Page 4: ...set limit value of the heat stress index a buzzer sounds and the LED lamp flashes to alert Screw hole for a tripod is equipped Useful to mount the tripod at measurement Accessories Carabiner belt atta...

Page 5: ...key to turn the main unit on Press it again to turn off MENU key Press this key to enter the setting mode SELECT key In measuring mode press this key to switch WBGT setting between outdoor and indoor...

Page 6: ...ed How to use Loading and Replacing Battery Before using the instrument for the first time install a new battery When low battery mark appears on the display replace the battery to new one Use a screw...

Page 7: ...section for one second with the buzzer sound and LED lamp flashes enter the measuring mode Have the instrument fully adapt to measuring ambient before measurement The heat index WBGT temperature humi...

Page 8: ...onment Environment Mark Usage Outdoor mark is not displayed When used outdoor place in the sun Indoor mark is displayed When used indoor or outdoor at the place not in the sun Keylock function To prev...

Page 9: ...s index of measurement environment can be easily checked The factory setting is set as the Heat stress prevention guidelines for exercise The Heat stress prevention guidelines for exercise 5 steps Alm...

Page 10: ...mode press the MENU key for longer than 2 seconds Alarm Function The alarm is triggered with sound of buzzer and blinking LED light when the Heat stress index exceeds the set value The factory settin...

Page 11: ...ding If the alarm sounds take the appropriate actions to prevent the heat stress Please refer to the Reference data for the actions of the heat stress prevention guidelines How to set alarm function P...

Page 12: ...the Heat stress index is the highest level Danger Press the MENU key for longer than 2 seconds to return to the measurement mode How to install the mounting accessories The instrument can be worn wit...

Page 13: ...0 2 x TG 0 1 x DB Indoors WBGT 0 7 x WB 0 3 x TG WB Wet bulb temperature TG Globe temperature DB Dry bulb temperature The Heat stress prevention guidelines for exercise compiled by Japan Sports Assoc...

Page 14: ...on of Heat Disorder During Sports Activities 2013 The Heat stress prevention guidelines for daily life complied by Japanese Society of Biometeorology WBGT Index Risk of occurrence in relation to physi...

Page 15: ...t work please contact us or the dealer from which the unit was purchased for assistance Trouble shooting Trouble Possible Cause Solution The power cannot be turned on The battery is exhausted Replace...

Page 16: ...S B7922 Class 2 Operation Ambient 0 to 50 C less than 95 rh no condensing Wind speed 0 3 to 3 0 m s Storage Ambient 10 to 50 C no condensing Power Requirement 3VDC Lithium coin battery CR2032 2 in par...

Page 17: ...3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english...

Reviews: