Sensor Threshold Level
Gap Sensor (Continued)
STEP PROCEDURE
6WULSWKHODEHOIURPWKHEDFNLQJDQGLQVHUWWKHEDFNLQJVWULSXQGHUWKH
VHQVRUDQGFORVHWKHODEHOOLG5HFRUGWKHYROWDJHVKRZQRQWKHWRSOLQHRI
WKH/&'SDQHO7KHYROWDJHUDQJHVPHDVXUHGVKRXOGEHZLWKLQWKH
IROORZLQJUDQJHV
,IWKHPHDVXUHGYDOXHVDUHRXWVLGHWKLVUDQJH\RXPD\KDYHWURXEOHILQGLQJ
DYDOXHWKDWZLOOZRUNSURSHUO\XQGHUDOOFRQGLWLRQV,IWKLVLVWKHFDVHD
KLJKHUTXDOLW\ODEHOPD\EHQHHGHGWRJHWDGHTXDWHSHUIRUPDQFHRUDGMXVW
956HH6HFWLRQ
&DOFXODWHWKHVWDUWLQJSRLQWYROWDJHXVLQJWKHIRUPXODDERYH
8VHWKH
/,1(
NH\WRVWHSWKHFRXQWHUWRWKHGHVLUHGVHWWLQJ7KHGLVSOD\
ZLOOLQFUHPHQWRQHVWHSIRUHDFKWLPHWKH
/,1(
NH\LVSUHVVHG,IWKH
/,1(
NH\LVKHOGGRZQIRUPRUHWKDQWZRVHFRQGVLWZLOODXWRPDWLFDOO\JRLQWR
WKHIDVWVFUROOPRGH7KHUHDGLQJZLOODGYDQFHWRDVHWWLQJRIWKH
PD[LPXPYROWDJHDIWHUZKLFKLWZLOODXWRPDWLFDOO\ZUDSDQGVWDUWDW´µ
DJDLQ,IDYDOXHRI´µLVVHWWKHSULQWHUZLOODXWRPDWLFDOO\VHWWKHOHYHO
EHWZHHQWKHWZRPHDVXUHGYROWDJHVHDFKWLPHWKHSULQWHULVSRZHUHGRQ
ZLWKODEHOVORDGHG
5HSHDWWKLVSURFHGXUHXVLQJYDOXHVVOLJKWO\KLJKHURUORZHUXQWLOWKH
RSWLPXPSHUIRUPDQFHLVREWDLQHG,I\RXFDQQRWILQGDVHWWLQJEHWZHHQWKH
KLJKDQGORZUHDGLQJVWKDWJLYHVDGHTXDWHSHUIRUPDQFHWKHQWKHODEHO
VWRFNKDVWRRPXFKYDULDWLRQLQLWVRSDFLW\DQGDEHWWHUTXDOLW\VWRFNVKRXOG
EHXVHG
2QFHWKHVHWWLQJLVFRUUHFWSUHVVWKH
)(('
NH\WRDFFHSWWKHVHWWLQJ
Backing with Label
Label Backing Only
2.0V to 3.5V