SATO CL4NX RIDF Configuration Manual Download Page 2

B)

Physical Antenna Position

When the Antenna Pitch is set to “Standard” in the printer’s RFID menu, adjust the physical position of the
antenna according to the settings required for the specific label and inlay used.

3  Set Labels and Carbon Ribbon. 

Refer to the sticker on the printer’s top cover, the help videos in the printer menu, and the Operator Manual for 
more information.

4  Confirm operation by printing/encoding a label.

Be sure to read the data and check that it is correctly encoded.

(a)

(b)

Rotate the dial (a) to align the pointer (b) with the label to 
be used. See under “Antenna Position” in the CL4NX UHF 
Inlay Placement & Configuration Table in the CL4NX UHF 
Inlay Configuration Guide.

RFID Printing Tips

A) Recommended no-print zone

Avoid printing barcodes or characters directly on top of an
RFID chip. The uneven surface will negatively affect print
quality.

B) Printing of RFID tag errors

The printer can be set to print an RFID tag error when there
is a problem with the recorded data, for example in a write
to a defective tag, in order to prevent accidental distribution
of a defective label. Depending on the error and the print
command paper size setting, a diagonal line or a cross will
be printed, together with a description of the error.

• List of errors printed

Message

Cause and Countermeasure

TAG NOT FOUND

Cause

Tag cannot be found, or reading in failed.

Countermeasure

Confirm inlay operation and check printer / antenna configuration.

WRITE TAG ERROR

Cause

Writing failed.

Countermeasure

Confirm inlay operation and check printer / antenna configuration.

PROTECT (TAG) ERROR

Cause 1

An attempt was made to write to a tag with the write lock set.

Cause 2

An attempt was made to write to a non-writable address.

Countermeasure

Use a label with the lock not set.

LOCKING ERROR

Cause

Lock processing failed.

Countermeasure

Check the label.

MULTI TAGS ERROR

Cause

Multiple tags captured simultaneously.

Countermeasure

Confirm inlay operation and check printer / antenna configuration.

DIFFER EPC ERROR

Cause

In a processing sequence, non-matching EPC found.

Countermeasure

Check the label.

RFID MODULE ERROR

Cause

Hardware error occurred.

Countermeasure

Contact your SATO reseller or technical support center.

15 mm

15 mm

Feed Direction

IC chip

I-Mark

RFID tag/label

Print object

inlay

Gap

Antenna

Recommended no-print zone

TAG NOT FOUND

Feed Direction

Extensive contact information of worldwide SATO operations can be found on the Internet at 
www.satoworldwide.com

CL4NX_RFID.fm  Page 40  Monday, March 10, 2014  7:26 PM

Reviews: