Instruction Manual
Waterproof Digital Thermometer
Model SK-270WP
No. 8078-00 with a hole for wall-mount type
No. 8078-20 without a hole for wall-mount type
S.01E
Page 1: ...Instruction Manual Waterproof Digital Thermometer Model SK 270WP No 8078 00 with a hole for wall mount type No 8078 20 without a hole for wall mount type S 01E...
Page 2: ......
Page 3: ...se this unit in water Do not use this unit in a place exposed to direct sunlight or near heating equipment Doing so may result in deformation of the casing or failure Do not use this unit in an enviro...
Page 4: ...tal thermometer to which a dedicated thermistor sensor probe can be connected Optional probes can be interchangeably connected with main unit 3 What in the box After unpacking please check the box con...
Page 5: ...probe it conforms to Protection level IP67 in JIS C 0920 and can be washed with running water NB This model is not suitable for use under water Impact resistance The outer protection rubber of the cas...
Page 6: ...red value is being held Low battery mark Blinks when battery power is insufficient MAX MIN Lights while the maximum minimum measured value is being displayed Lights the mark and set number in the HACC...
Page 7: ...r replace the batteries with the following procedure 1 Rotate the screw on the battery lid on the back of the main unit counterclockwise using a blade screwdriver or a coin until it comes free and the...
Page 8: ...he Thermometer The unit comes with a vinyl cover to keep it clean and to protect the unit from damage if dropped 1 Open the mouth of the vinyl cover and place the unit in it so that the side with a sl...
Page 9: ...section serial number of the unit and the calibration date are indicated Then measured value is indicated temperature measurement mode NB If the probe is disconnected when power is turned on error me...
Page 10: ...mount the unit on a wall No 8078 22 does not have the hole for wall mount After fitting the screw on a wall or a column mount the unit by using the hole for mount NB Shake the unit lightly to the left...
Page 11: ...IN key again MIN lights and to the lowest temperature value is indicated Press the MAX MIN key again MIN goes out and switch back to the real time display Under the temperature measurement mode or the...
Page 12: ...CP1 temperature setting The initial value for temperature C is set to 75 To change the preset temperature use the MAX MIN key to increase the value or the HOLD key to decrease the value After setting...
Page 13: ...d HACCP 3 Select the mode to be used Perform temperature measurement When the temperature reaches the set point the timer starts counting down When the time reaches the set point the LED turns on and...
Page 14: ...Measured value is lower than display range Internal processing is abnormal Remove batteries Then load batteries again after leave it for a while Replace the batteries to new ones A sensor signal is ab...
Page 15: ...0 Protection IP 67 rated when the probe is connected to the unit Operation ambient 10 to 60 C less than 80 rh no condensing Storage ambient 10 to 60 C no condensing Operational Functions HOLD MIN MAX...
Page 16: ...3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english...