background image

Warnings

 

 

The index of the heat stress monitor is applicable to the air control or health management and is not 

the devise to directly prevent heat attack.   

 

Do  not  solder,  short-circuit, disassemble,  heat  or  fire  a  battery.  Doing  so  may  cause  an  exothermic 

heat, a leakage of battery fluid or an explosion. 

 

If the leaked fluid is spilt on your clothes or your skin, wash it off with water and if it gets into your 

eyes, wash it off with clean water and seek a medical attention immediately. 

 

Batteries  pose  a  danger  of  suffocation  or  poisoning  if  swallowed.  Keep  batteries  out  of  reach  of 

children. 

 

When  the  battery  is  not  in use,  insulate  the terminals  with tape  to prevent  contact  with  other  metal 

objects or batteries. Otherwise, a short circuit may occur and cause a fire or explosion. 

 

For  environmental  conservation,  dispose  used  batteries  in  compliance  with  local  rules  and 

regulations.

 

Cautions 

 

Do not break the LCD panel to avoid any injuries. 

 

Never  touch  the  liquid  inside  even  if  the  LCD  panel  broke or  a battery  leaks.  Doing  so  may  cause 

skin  irritations.  If  swallowed,  wash  out  with  water  and  seek  medical  attention  immediately.  If  the 

liquid  comes  in  contacts  with  the  eyes  or  skin,  wash  them  with  clean  water  for  at  least  15  minutes 

and seek a medical attention. 

 

If the instrument is in use for a long period of time, remove the batteries to avoid any leakage of the 

battery fluid which could damage the instrument. 

 

 

Specifications 

Name 

No. 1075-00 Digital Thermohygrometer with Heat Stress Monitor 

Model 

PC-7900GT 

Measuring Range 

Temperature 

:  -9.9 to 50.0

 

Humidity 

:  20 to 90% rh 

Display Range 

Temperature 

:  -9.9 to 50.0

C   

 

Humidity 

:  20 to 90% rh 

Accuracy 

Temperature 

:  ±1

 

Humidity 

:  ±5% at 40 to 70% and 20 to 30

 

 

  ±8% at other than above 

Resolution 

Temperature 

:  0.1

 

Humidity 

:  1%rh   

Operating Condition 

Main body 

:  -9.9 to 50.0

C, less than 90% rh (no condensing) 

Storage Condition 

Main body 

:  -9.9 to 50.0

C, less than 90% rh (no condensing) 

Sampling Time 

Every 1 min. 

Accuracy of clock 

Within ±30 sec. per month 

Display Functions 

Temperature   

 

Lo

 is displayed

 

at less than -9.9

C and 

Hi 

at more than 50

R. Humidity: 

 

Lo

 is displayed

 

at less than 20%rh and 

Hi 

at more than 90%rh 

(“---“ is displayed at less than 17%rh and at less than 30%rh at less than 15

C) 

 

MAX/MIN temperature and humidity,   

 

Clock (hour, minute    * switchable 12/24 hour) 

 

Heat Stress Monitor (scales of one to five) 

                                          Low battery mark 

Power Requirements 

AAA” size manganese battery 

×

 2 

Battery Life 

approximately one year (at 20

C, 50%rh) 

Materials 

ABS reign, Acrylic resin (main unit) 

Dimensions 

(W) 135 

 (H) 91

 (D) 67 mm 

Weight 

approx. 160g (including a battery) 

Standard Accessories 

  “AAA” size manganese battery 

×

 2

 

No. 3, Nishi Fukudacho, Kanda, Chiyodaku, Tokyo 101-0037 JAPAN 

TEL:+81(0)3-3254-8117    FAX:(0)3-3254-8123    URL:

 

http://www.sksato.co.jp/english/ 

Reviews: