Thank you for purchasing the digital thermohygrometer with heat stress monitor model PC-7900GT. 

This  product  is  designed  to  measure  temperature  and  humidity  of  atmosphere  and  indicate  the  heat 
stress exposure with 5 steps.    Do not use it for other purposes. 

This heat stress monitor is applicable for household use only.    The index is just for the reference to 
control air-condition or manage health condition. 

Read this manual thoroughly before use and keep it in a safe place for your future references. 

 
Names of section 

 

 Front view 

 Rear view

 

 

 

 

 

 

 

Replacing Batteries 

When the battery power becomes low, the display dims and measurement errors occur.    Replace all 

two batteries to new ones. 

* The low battery mark (

) will appear on the LCD when replacement of batteries is required.   

(1)

 

Remove the battery compartment lid by sliding it downward. 

(2)

 

Pull the pickup string to get out the battery compartment.     

Be careful not to break the string with a strong pull. 

(3)

 

Remove  the  used  batteries  and 

load  two  new  AAA  batteries  with 

correct  polarity 

  (+)  (-) 

  as 

instructed in the battery 

          compartment. 

(4)

 

Set in the battery compartment and 

close the lid. 

 
 

Dispose of used batteries according to your local waste disposal regulations for environmental 
conservation. 
 

System Reset 

Use the reset key to return correct indication.    This key is useful when 
the temperature or humidity values is inaccurately indicated by inference 
of the electrostatic action or when the batteries are replacement. 
 
In this case, data are erased and the time displays as 00:00.     
Set the time with the following procedure. 

 

Press the RESET key with a thin stick like a toothpick. 
   

 

How to Use 

 

Insert the batteries at the start.         

                                                     

                                           

 

 

 

 

 

 Setting Time 

Press the SET key for three sec. to change to the time setting mode. 

(1)

 

“24H” brinks.    Press the MAX or MIN key to select 
24H or 12H display.   

(2)

 

Press  the  SET  key  and  “hour”  starts  flashing.    Press  the  MAX 

(numbers up) or MIN (numbers down) key to set the hours. 

(3)

 

Press  the  SET  key  again  and  minute  starts  flashing.    Press  the 

MAX  (numbers  up)  or  MIN  (numbers  down)  key  to  set  the 

minute. 

(4)

 

Press the SET key and setting of the time is now complete. 

Note:

  If no key is pressed for one minute, the setting of the time automatically exits. 