26
VERSA Plus LTE
SATEL
If it is necessary to de-energize the control panel, turn off the main power supply (AC)
first, and the backup power supply (battery) afterwards. Observe the above described
procedure when reconnecting the power supply.
5.12.4 Emergency procedure of the control panel start-up
If the control panel fails to start properly, keypads are not supported, codes are not accepted
by the control panel etc., despite all connections having been made correctly, follow the steps
below:
1. Turn off the control panel power supply (first disconnect the AC power, and then the
battery) and make sure the control panel is not connected to the computer by a USB
cable.
2. Put a jumper on the pins located on the control panel mainboard (designated
in Fig. 2
– p. 9).
3. Turn on the control panel power supply (first connect the battery and then the AC power).
4. Wait a few seconds and remove the jumper from the pins. The control panel will enter the
service mode. The service mode menu will be displayed on the keypad with the lowest
address (in the case of a wireless keypad, the menu will be displayed on pressing any
key).
If the S
ERVICE MODE FROM
RESET
PINS
option is disabled in the control panel then,
depending on the type of keypad in which the lowest address is set:
−
LCD: the
,
and
(of the second partition) LEDs will be lit, and the
message “Restore factory settings ? 1=Yes” will come up on the display,
−
LED: the
and
(of the second partition) LEDs will be lit and the
LED will
be flashing rapidly.
Pressing the
key will reset the control panel to its factory settings, but will enable
entering the service mode.
5.12.5 First steps after starting-up the control panel
Having started the control panel with factory defaults:
1. Set individual, correct addresses in the keypads.
2. Run the identification function for devices connected to the communication bus of the
control panel.
Programming the control panel settings will only be possible after completion of the above
steps.
5.13 Programming addresses for the hardwired keypads
Each keypad connected to the control panel must have an individual address set within the
0 to 5 range. By default, address 0 is set in all wired keypads. When started with factory
default settings, the control panel will support all keypads connected to the bus, irrespective
of what addresses are set in them. Thus it is possible to set correct individual addresses in
the keypads.
Remember to program an individual address if a new keypad is connected to the
already functioning alarm system.
5.13.1 Programming the address by means of the service function
The address programming function can be started from either a wired or wireless
keypad, but it will only allow setting addresses in the wired keypads.