SPL-TO 

OPTICAL TAMPER DETECTOR

 

 

spl-to_en 03/17 

The SPL-TO is a device intended to detect an attempted covering the piezoelectric 
transducer in sirens with mounting foam. It is designed for use together with the following 
sirens of SATEL's manufacture (SPL type): 
SPL-2030, SPL-5010, SPL-5020. 
Operation of the SPL-TO is based on the infrared barrier principle. The optical system 
consists of the transmitting part and the receiving part. The transmitting diode sends a beam 
of IR radiation in pulse mode to the receiving diode. If there is an obstacle on the path of IR 
beam, the detector opens the relay contacts and lights up the TAMPER LED. The detector 
can be used for making an independent tamper circuit. 

1.  Description of the Detector 

 
 
 
 
 
 

Figure 1 

TAMPER 

TMP  TMP 

COM 12V 

Explanations for Figure 1: 

1

 -  TAMPER LED (red). The LED is ON if there is no communication between the 

transmitting and receiving LEDs. The LED lights up approx. 2 seconds after the infrared 
beam was interrupted, and goes out immediately after removal of the obstacle. 

2

 -  mounting holes. 

- relay. 

Description of terminals: 

TMP

 -  tamper contact terminals. 

12V

  -  power supply input. 

COM

 -  common  ground. 

2.  Installation of the Detector  

Caution: Before starting hook-up of  the optical tamper detector to the already existing 

system, it is recommended that the whole system be deenergized. 

1.  Screw down the SPL-TO board to the siren housing base (from outside).  
2.  Connect power supply cables to the terminals COM and 12V. 
3.  Cut the TMP terminals in the tamper circuit of alarm control panel. It is also possible to 

connect the tamper circuits of the SPL-TO and the siren. 