64
SATEL OY
// SATELLAR MANUAL // RADIO UNIT // USER GUIDE // V. 1.8
10. Troubleshooting
3
Name
Description
Code
LED Required action
ERROR_CAT_FPGA_
COMM
Error in FPGA MCU
communication
0 0010
(2)
•
•
•
•
•
•
•
•
Switch to the previous firmware
version. If not possible the unit should
be sent to service.
ERROR_CAT_BOARD_
VERSION
PWB version not
compatible with the
firmware version
0 0011
(3)
•
•
•
•
•
•
•
•
Switch to the previous firmware
version. If not possible the unit should
be sent to service.
ERROR_CAT_HW_INIT_
GENERAL
Problem in HW
initialization (other than
memory related)
0 0100
(4)
•
•
•
•
•
•
•
•
Reboot the unit. If the problem
remains the unit should be sent to
service.
ERROR_CAT_VOLTAGE
Internal voltage
monitoring has detected
out-of-limits values for
certain voltages
0 0101
(5)
•
•
•
•
•
•
•
•
Reboot the unit. If the problem
remains the unit should be sent to
service.
ERROR_CAT_PA_
CURRENT_HIGH
RF power amplifier
current has exceeded
the limit and the
transmitter has been
shut down to protect the
electronics
0 0110
(6)
•
•
•
•
•
•
•
•
a) Check the antenna impedance
match and if needed improve the
match.
b) Wait for a while and restart the data
transmission. If the problem remains
the unit should be sent to service.
ERROR_CAT_PA_TEMP_
HIGH
RF power amplifier
temperature has
exceeded the limit and
the transmitter has been
shut down to protect the
electronics.
0 0111
(7)
•
•
•
•
•
•
•
•
a) Check the ambient temperature. It
might be too high.
b) Wait for a while and restart the data
transmission. If the problem remains
the unit should be sent to service.