background image

SATEL 

MPD-300 

  Do not install the detector outdoors (A). 

  Install the detector at the recommended height (B). 

  When  choosing  the  installation  location,  keep  in  mind  that  the  detector  performance  will 

be  the  best  where  the  expected  direction  of  the  intruder  movement  will  be  across  the 
coverage pattern (C). 

  Do not install the detector in places where it will be exposed to direct sunlight  (D) or light 

reflected from other objects (E). 

  Do not point the detector towards fans (F), air conditioner (G) or heat sources (H). 

4  Installation 

There  is  a  danger  of  battery  explosion  when  using  a  different  battery  than 
recommended by the manufacturer, or handling the battery improperly. 

Be  particularly  careful  during  installation  and  replacement  of  the  battery. 
The manufacturer  is not  liable  for  the  consequences  of incorrect  installation  of 
the battery. 

The  used  batteries  must  not  be  discarded,  but  should  be  disposed  of  in 
accordance with the existing rules for environment protection. 

1.  Remove the front cover (Fig. 7). 

2.  Configure the detector using the jumpers. 

 

3.  Install the battery in the detector. 

4.  Register  the  detector  in  the  system  (see:  PERFECTA  /  VERSA  control  panel  installer 

manual, MTX-300 controller manual or MICRA module manual). 

5.  Place the detector at the location of its future installation. 

6.  Close  and open both tamper  switches.  If  the  transmission from  the  detector  is  received, 

continue with the installation. If the transmission from the detector is not received, select 
a different  mounting  location  and  repeat  the  test.  Sometimes,  it  is  sufficient  to  shift  the 
detector ten or twenty centimeters. 

7.  Remove the electronics board (Fig. 8). 

8.  Make the openings for screws in the back tamper unit (Fig. 9). 

9.  Secure the back tamper unit to the wall (Fig. 9) or a bracket fastened with screws to the 

wall or ceiling  (Fig.  10). The wall plugs (anchors) delivered with the device  are intended 

Summary of Contents for micra MPD-300

Page 1: ...MPD 300 Wireless passive infrared detector Firmware version 2 00 mpd 300_en 06 20 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Page 3: ...ption 2 Radio communication 2 Alarms 2 Operating modes 2 Test mode 2 LED 3 Supervision of motion detection system 3 Battery status control 3 Electronics board 3 3 Selecting a mounting location 4 4 Ins...

Page 4: ...the detector sends information about its state periodical transmission Additional radio transmissions take place as a result of alarm Alarms The detector will report alarm after detecting a motion in...

Page 5: ...an alarm during periodical transmission The alarm will keep going until the fault is cleared long violation Battery status control When the battery voltage is below 2 75 V information about low batter...

Page 6: ...ED indicator tamper switch activated by detector removal from the back tamper unit tamper switch activated by cover removal PIR sensor dual element pyrosensor scale for positioning of PIR sensor again...

Page 7: ...The used batteries must not be discarded but should be disposed of in accordance with the existing rules for environment protection 1 Remove the front cover Fig 7 2 Configure the detector using the ju...

Page 8: ...he mounting screw hole facilitates positioning of the electronics board depending on the detector installation height Fig 12 12 Close and open the tamper switch that detects the cover removal to enabl...

Page 9: ...n 55 A Maximum current consumption 58 mA Detectable speed 0 3 3 m s Warm up period 15 s Recommended installation height 2 4 m Coverage area normal sensitivity 14 m x 12 m 86 high sensitivity 16 m x 18...