Do not install the detector outdoors (A).
Install the detector at the recommended height (B).
When choosing the installation location, keep in mind that the detector performance will
be the best where the expected direction of the intruder movement will be across the
coverage pattern (C).
Do not install the detector in places where it will be exposed to direct sunlight (D) or light
reflected from other objects (E).
Do not point the detector towards fans (F), air conditioner (G) or heat sources (H).
4 Installation
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery.
The manufacturer is not liable for the consequences of incorrect installation of
the battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
1. Remove the front cover (Fig. 7).
2. Configure the detector using the jumpers.
3. Install the battery in the detector.
4. Register the detector in the system (see: PERFECTA / VERSA control panel installer
manual, MTX-300 controller manual or MICRA module manual).
5. Place the detector at the location of its future installation.
6. Close and open both tamper switches. If the transmission from the detector is received,
continue with the installation. If the transmission from the detector is not received, select
a different mounting location and repeat the test. Sometimes, it is sufficient to shift the
detector ten or twenty centimeters.
7. Remove the electronics board (Fig. 8).
8. Make the openings for screws in the back tamper unit (Fig. 9).
9. Secure the back tamper unit to the wall (Fig. 9) or a bracket fastened with screws to the
wall or ceiling (Fig. 10). The wall plugs (anchors) delivered with the device are intended