Satel KNX-BSA12H Manual Download Page 6

KNX-BSA12L 

• KNX-BSA12H 

SATEL 

The  buttons  are  also  used  for  restoring  the  module  to  its  factory  default  settings 
(see 

“Restoring module factory default settings”). 

 red  LED 

–  ON  during  physical  address  assignment  via  the  ETS  program  and  flashes 

when  the  service  mode  is  active.  Address  assignment  can  be  activated  manually  by 
using the 

 button on the enclosure or remotely from the ETS program. 

 programming  button  (used  for  physical  address  assignment).  The  button  can  also  be 

used to start the service mode in the module 

(see “Service mode”). 

 terminal to connect KNX bus. 

2.1  Enclosure 

 

Electronics  of  the  KNX-BSA12L  and  KNX-BSA12H  modules  is  installed  in  enclosures  of 
identical shape and dimensions. The enclosures only differ in their panels for manual control 
of  channel  state.  The  figure  shows  enclosure  dimensions  based  on  the  KNX-BSA12L 
module. The module takes up 4 units on the DIN rail (35 mm). 

2.2  Operating the module manually 

Manual  operation  allows  you  to  control  the  movement  of  blinds/shutters  using  the  buttons 
located  on  the  module  enclosure  (see  p. 3).  The  blind/shutter  control  is  possible  after 
configuring the module settings in the ETS program. 

The  weather  alarm  (see  “Weather  alarms”  p. 25)  and  position  forcing  function  (see 
“Position forcing” 
p. 26) block the manual operation of the module. The manual control 
is then interrupted and the blind/shutter is set to the position defined as the reaction to 
the weather alarm / position forcing function. 

2.3  Service mode 

The  service  mode  allows  checking  whether  connections  between  the  module  and  the 
blind/shutter  motors  are  made  properly,  and  whether  the  module  correctly  detects  the 
blind/shutter  movement.  You  can  use  the  service  mode  before  configuring  the  module 
settings in the ETS program (e.g. to set limit switches when installing the blind/shutter). 

Summary of Contents for KNX-BSA12H

Page 1: ...KNX BSA12L 24 VDC KNX BSA12H 230 VAC Blind shutter Actuator Firmware version 1 02 knx bsa_en 09 20 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...ized by the manufacturer shall void your rights under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and softw...

Page 3: ...guring global parameters 7 4 2 1 Weather alarms 8 4 3 Configuring channels 9 4 3 1 Blind shutter operating parameters 10 Motor 17 Shutter awning window 18 Venetian blind 18 4 3 2 Functions 20 Scene 1...

Page 4: ...s are configured in the ETS program in the same way for both modules except for defining operation of the vertical blinds as only the KNX BSA12L module supports this blinds 1 Features Communication wi...

Page 5: ...ror is automatically cleared when the blind shutter reaches the end position in the opposite direction to that in which it was moving when the channel reported an error Continuous operation for too lo...

Page 6: ...nsions based on the KNX BSA12L module The module takes up 4 units on the DIN rail 35 mm 2 2 Operating the module manually Manual operation allows you to control the movement of blinds shutters using t...

Page 7: ...12H reverse the wires controlling the direction of motor rotation Check the current consumption by the blind shutter motor if it is lower than the minimum current detected by the module the blind shut...

Page 8: ...eu ets must be imported into the program For detailed information on how to configure the module refer to section Configuring the module 3 1 Wiring diagram 4 Configuring the module Working parameters...

Page 9: ...ition control function will not be able to change the blind shutter position until the alarm is called off 4 2 Configuring global parameters The main working parameters of the module are defined in th...

Page 10: ...enetian blind vertical blind awning window Selecting the type of blind shutter will enable the communication objects to control its movement and display the Channel B tab The Vertical blind type of bl...

Page 11: ...me of the Frost alarm object 0 65535 seconds With the monitoring disabled field value 0 the alarm will only be triggered by receiving the Alarm telegram As good practice indicates monitoring time of t...

Page 12: ...lind shutter travel time may be detected by the module automatically recommended or can be determined based on a measurement taken The travel time is the time during which the blind shutter can be mov...

Page 13: ...o the upper end position It is advisable to automatically detect the time of movement by the module for all blinds shutters that make it possible Slat adjustment time This parameter applies to the sla...

Page 14: ...he slat position and adjustment time for a vertical blind only for the KNX BSA12L module Description of parameters Depending on the type of blind shutter selected for the channel A different parameter...

Page 15: ...select the manual detection fields that allow you to enter the measured values will be displayed in the tab see Shutter awning window and Venetian blind If you select manual detection for a blind shu...

Page 16: ...position at which the blind shutter can stop see Fig 10 0 100 default 10 If after stopping the distance between the blind shutter and the target position is greater the channel will report an error in...

Page 17: ...bstacle detection by smart motor Value 0 disables the cyclic telegram sending Interval of cyclic position sending frequency of sending a telegram with information about current blind shutter position...

Page 18: ...Move up down central communication object Changing the object value will trigger a channel response as a result of which the blind shutter will be moved up or down according to the value saved in the...

Page 19: ...the channel Disable Enable If you select Enable the Weather alarms tab will be displayed The parameter is available when the weather alarm functions are enabled in the module Weather alarms parameter...

Page 20: ...be taken Travel time up shutter travel time from the lower to the upper end position see Fig 4 6 and 7 0 480000 milliseconds The field is available if the yes option is selected for the Travel time in...

Page 21: ...option is selected for the Travel time in two directions parameter Travel time down time of travel of Venetian blind from the upper to the lower end position see Fig 4 0 480000 milliseconds The field...

Page 22: ...to control the position of blinds by defining the correct percentage values of opening for the first and second scenes from the pair percentage value of opening before calling scenes channel A 0 chann...

Page 23: ...with value 0 from the Call scene 1 bit 1 2 communication object 0 100 0 upper end shutter position 100 lower end shutter position see Fig 4 6 and 7 Scene 2 delay time that must elapse from receiving t...

Page 24: ...ind position 100 lower end blind position see Fig 4 and 5 Scene 1 position of slats position to which the slats will be set in response to the telegram with value 0 from the Call scene 1 bit 1 2 commu...

Page 25: ...from the bus If the object value has not been changed by the learning function the default value will be set Initial values for the other scenes are defined in the same way as for the 1 2 pair Scene...

Page 26: ...g scenes from bus parameter default value defined in the program If the object receives a telegram with the scene number Scene 1 8 number field the shutter is set to position corresponding to the valu...

Page 27: ...larm i e their hierarchy where 1 highest priority 3 lowest priority 1 Frost 2 Rain 3 Wind 1 Frost 2 Wind 3 Rain 1 Rain 2 Frost 3 Wind 1 Rain 2 Wind 3 Frost 1 Wind 2 Frost 3 Rain 1 Wind 2 Rain 3 Frost...

Page 28: ...he object assumes the value 1 the blind shutter will be set to the position defined and the channel will be locked Unlocking of the channel is only possible when the object assumes the value 0 When un...

Page 29: ...ountdown will be started again reset The blind shutter position set by using this object can only be changed as a result of a higher priority alarm see Weather alarms or by the position forcing functi...

Page 30: ...absolute position slats percentage 1 byte DPT 5 001 C W The object will be enabled if you select Enable for the Central absolute position parameter in the tab for configuring the settings of the chann...

Page 31: ...in the Interval of cyclic device error alarm sending field in the Global tab Telegram 1 error in one of the channels 0 module is working correctly Flag C communication R read W write T transmit U upda...

Page 32: ...a 1 bit object 0 step up by the value defined in the Step value field 1 step down by the value defined in the Step value field when the blind shutter or slats are moving 0 STOP 1 STOP 19 Channel A De...

Page 33: ...shutter in the Channel A field Global tab It enables sending a telegram with information about the current position of the blind shutter The telegram is always sent after the travel is completed The p...

Page 34: ...etian blind Telegram 1 error in the channel 0 channel is workin correctlly Flag C communication R read W write T transmit U update Functions Channel communication objects No Object name Object functio...

Page 35: ...ject with number X Y enables the current blind shutter position percentage value of opening to be assigned to the 1 bit scene with number X and Y Telegram 0 current blind shutter position will be assi...

Page 36: ...L 24 VDC KNX BSA 12H 230 VAC In rated current KNX BSA 12L 6 A KNX BSA 12H 6 A Connections Maximum wire cross section 2 5 mm2 Maximum tightening torque 0 5 Nm KNX parameters Maximum time of reaction to...