The INT-RX expansion module is designed for operation in the intruder alarm systems. It can 
work in conjunction with the SATEL made control panels: INTEGRA (with firmware version 
1.05 or newer) and VERSA. The module enables key fobs to be assigned to the security 
system users. Using the key fob enables up to 6 functions to be executed. The device 
supports up to 248 key fobs manufactured by the SATEL company (the number of supported 
key fobs depends on the control panel). Transmission from the key fob is dynamically 
encoded using the K

EE

L

OQ

® 

technology, which ensures both the operation safety and 

immunity to spurious control signals, coming from other devices. The module can support all 
key fobs manufactured by SATEL, but only the T-4 and P-4 models enable the module 
features to be fully utilized. 

1.  Description of electronics board 

 

+12V

COM CLK DAT

RS232

(TTL)

1

2

3

4

5

6

7

 

Fig. 1. View of the INT-RX expansion module electronics board. 

 
Explanations for the figure: 
1 – 

antenna

2 – 

superheterodyne receiver

, high sensitivity, immune to spurious signals. 

3 – 

tamper contact

4 – 

two-color

 

LED

 indicating as follows: 

  steady green light – normal communication with the control panel; 

  blinking green light – no communication with the control panel; 

  steady red light – the expansion module is receiving transmission from a key fob 

with good battery; 

  blinking red light – the expansion module is receiving transmission from a key fob 

with low battery. 

Summary of Contents for INT-RX

Page 1: ...tion safety and immunity to spurious control signals coming from other devices The module can support all key fobs manufactured by SATEL but only the T 4 and P 4 models enable the module features to b...

Page 2: ...rder to determine the expander address add up the values set on individual switches as shown in Table 1 DIP switch number 1 2 3 4 5 Numerical value for switch in ON position 1 2 4 8 16 Table 1 DIP swi...

Page 3: ...le interaction with INTEGRA control panel The key fob data are stored in each module If you connect the module which contains key fob related data to the alarm control panel key fobs will be automatic...

Page 4: ...S menu or on the EDIT KEYFOBS button which is available after selecting the INT RX expansion module from the list of devices tab HARDWARE window STRUCTURE Prior to adding a new key fob you have to rea...

Page 5: ...ram interaction with INTEGRA control panel Reading the serial number during transmission 1 Click your mouse on the field in the S N column next to the name of user to whom you want to assign a key fob...

Page 6: ...system By using a key fob you can control up to 6 zones in the security alarm system The zones should not physically exist and the type of line programmed for them must be different from NOT USED and...

Page 7: ...means of LCD keypad INTEGRA 1 06 or later Enabling disabling generation of events for particular key fob buttons is possible by using the RX EVENTS function which is available when adding editing admi...

Page 8: ...ng key fobs and assigning functions to the buttons Key fobs can be added removed by the service as well as by users having the USERS EDITING authority level In order to add a key fob enter its serial...

Page 9: ...The REMOVE KEY FOBS available in the service menu SERVICE MENU X2 HARDWARE X1 KPDS EXPS X9 REMOVE K FOBS makes it possible to clear all key fob related data in the INT RX expander connected to the co...

Page 10: ...panels as a part of intruder alarm system The product is in conformity with the following EU Directives EMC 2004 108 EC R TTE 1999 5 EC The product meets the requirements of harmonized standards EMC E...

Reviews: