Satel INT-RX-S Manual Download Page 4

4 INT-RX-S 

SATEL 

5.1  433 MHz keyfob management using the DLOADX program 

You can manage the keyfobs in the "Versa – Structure" window, "Hardware" tab, after clicking on the 
INT-RX in the list of devices. Before making any changes, click on the “Read” button, and after 
making the changes – on the “Write” button (the data relating to keyfobs are not read after clicking on 

the 

 or saved after clicking on the 

 in the DLOADX program main menu). 

Notes: 

 

Removing a keyfob only clears its serial number, but not its settings. If a new keyfob is added to 
the user, it will have the same settings as the removed one. 

 

You can delete all keyfobs, including their settings, using the R

EM

.RX

 K

-

FOBS

 function, available in 

the keypad service mode (

2. H

ARDWARE

 

1. K

PDS

.

 

&

 EXPS

.

 

9. R

EM

.RX

 K

-

FOBS

). 

You can add or delete keyfobs in the same way as when using the expansion module with the 
INTEGRA / INTEGRA Plus control panel. 

Assigning a function to keyfob button (combination of buttons) 

1.  Right click on the field corresponding to the button (combination of buttons). The list of functions 

will be displayed. 

2.  Click on the function to be run by the keyfob button (combination of buttons). 

6.  Work with the PERFECTA 16 / PERFECTA 32 control panel 

Using a keyfob, the user can run up to 6 functions. After adding a keyfob, default functions are 
assigned to its buttons. You can change them to other ones. 
To manage the keyfobs, you can use a keypad (when adding or editing a user – refer to the control 
panel user manual) or the PERFECTA

 

S

OFT

 program (“Users” tab). 

7.  Work with the ACCO-NT control panel 

For information on how the expansion module works with the ACCO-NT control panel and how 
keyfobs can be added and removed, refer to the ACCO NET system documentation. 
For keyfob management info, refer to the ACCO-WEB application documentation. 

8.  Specifications 

Supply voltage ..................................................................................................................12 V DC ±15% 
Standby current consumption........................................................................................................ 24 mA 
Maximum current consumption ..................................................................................................... 29 mA 
Operating frequency band for keyfobs .................................................................. 433.05 ÷ 434.79 MHz 
Number of supported keyfobs ............................................................................................................248 
Supported keyfobs...............................................................MPT-350, MPT-300, P-2, P-4, T-1, T-2, T-4 
Environmental class according to EN50130-5........................................................................................II 
Operating temperature range ............................................................................................ -10°C...+55°C 
Maximum humidity........................................................................................................................ 93±3% 
Enclosure dimensions ................................................................................................. 24 x 110 x 27 mm 
Weight ...............................................................................................................................................30 g 
 

The declaration of conformity may be consulted at www.satel.eu/ce 

 

SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gda

ń

sk • POLAND 

tel. +48 58 320 94 00 

www.satel.eu 

Reviews: