![Satel INT-R Manual Download Page 10](http://html1.mh-extra.com/html/satel/int-r/int-r_manual_1200632010.webp)
10 INT-R
SATEL
1 long beep every 3 seconds, followed by a series of short beeps for 10 seconds
and 1 long beep
– exit delay countdown (if the delay time is shorter than 10 seconds, only
the final sequence of short beeps will be generated).
A sequence of 7 beeps of diminishing duration, repeated every few seconds
– auto-
arming delay countdown.
1 short beep every 150 ms
– long open door.
2 short beeps every second
– entry delay countdown.
Continuous beep
– alarm.
1 long beep every second
– fire alarm.
Note:
If the device is working as the CA-64 SR expander, which supports the CZ-EMM
readers manufactured until May 2005, the alarm will be signaled in the same way as
the fire alarm, i.e. by a long beep every second.
Beeps generated after reading the card / chip code
1 short beep
– confirmation of the card / chip code readout.
2 short beeps
repeated three times
– the user of the given card / chip should change the
code.
3 short beeps
– depending on the current partition status:
– starting the arming procedure (which is equivalent to arming if no exit delay has been
programmed for the partition),
– disarming and/or alarm clearing.
4 short beeps
and 1 long beep
– confirmation of:
– turning on the relay (which can be accompanied by disarming / alarm clearing);
– turning off the relay;
– activating the 24.
MONO
SWITCH
type output;
– switching over the 25. BI
SWITCH
type output;
– guard round;
– temporarily blocking the armed partition.
1 long beep
– refusal of arming (the installer can configure the alarm system so that the
arming is impossible when e.g. a zone is violated in the partition, or a failure has
occurred).
2 long beeps
– unknown card / chip.
3 long beeps
– refusal to execute the function.
5. Specifications
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption ........................................................................................110 mA
Maximum current consumption ......................................................................................150 mA
Relay contacts rating (resistive load) ................................................................... 5 A / 30 V DC
Environmental class.................................................................................................................II
Operating temperature range.............................................................................-10 °C...+55 °C
Maximum humidity ..........................................................................................................93±3%
Dimensions ........................................................................................................... 140 x 68 mm
Weight.................................................................................................................................80 g