Figure 3. Entering the SIM card into its socket

 

It is suggested that the power supply be located within 3 m from the module. 
If the supply voltage is lower than 9.8 V, restart of the module will follow. Therefore, be 
careful that the module supply voltage never drops during operation below 9.8 V at the 
maximum current consumption. 

6. O

PERATION OF THE MODULE WITH ALARM CONTROL PANEL AND STATIONARY 

TELEPHONE

 

As shown in Figure 1, the module is to be directly connected to the control panel’s public 
telephone line terminals.  
It maintains impedance and voltage across the R-1 and T-1 terminals as necessary for 
correct operation of the telephone set. The terminals can be automatically deenergized in 
case of a loss of communication with the base station (which is accompanied by operation of 
the FLT trouble indicator – see: programming function No. 17). 
When the control panel goes "off-hook", or when a user lifts the handset of a telephone 
connected to the terminals T-1 and R-1, the module will generate the continuous dialing tone 
and receive the tone or pulse dialing signals (similarly as the telephone exchange). 
The telephone number can include digits and special characters: 

#

,

 *

,

 +

. The phone number 

should be dialed just like from a cellular phone, as required by the operator of the network 
into which the telephone is logged. It is recommended that the number begin with the "+" 
character and country code prefix (48 for Poland). Sometimes you can dial just the mobile 
phone number, or the area code and stationary telephone number. 
Examples: 
[*][0][4][8][5][0][1][1][2][3][4][5][6] –  connection to mobile phone (with prefix "+48") 
[5][0][1][1][2][3][4][5][6] – 

connection 

to 

mobile phone (number without prefix) 

[5][8] [1][2][3][4][5][6][7] 

–  connection to stationary telephone, (in this example, 58 

is location area code) 

If the first four digits of the dialed number correspond to the pre-programmed "

pager station 

number

", the module goes to the procedure of receiving the alphanumeric message and 

sending it as an 

SMS text message

 (see section 

Sending SMS messages

). Checking of 

the first four digits is always performed. 
When connection is established by the cellular telephone, the module will transmit LF audio 
signals between the extension line T-1, R-1 terminals and the cellular telephone. After the 
handset is lifted by the subscriber the connection is established with, the module changes 

1. slide the card 

carrier up 

3. press the carrier to the 

plate and slide the 
carrier down to fix it in 
position

2. turn the carrier aside and

slide the card into the
guides 

SIM card 

Summary of Contents for GSM LT-2

Page 1: ...COMMUNICATION MODULE GSM LT 2 USER MANUAL Program version 2 12 gsmLT 2_en 10 10...

Page 2: ...tel 48 58 320 94 00 fax 48 58 320 94 01 Product description Communications module used to simulate PSTN line over GSM network allowing for alarm transmission in case of a failure or lack of telephone...

Page 3: ...THE INPUTS 8 9 MESSAGING 10 9 1 SMS MESSAGES 11 9 2 CLIP 11 10 TRANSMITTING SMS MESSAGES 12 10 1 DESCRIPTION OF THE PROCEDURE FOR CONVERTING PAGER MESSAGE INTO SMS MESSAGE 12 10 2 SENDING SMS MESSAGES...

Page 4: ...alarm control panel support of DLOAD64 GUARD64 DLOADX and GUARDX programs Operation with PBX telephone exchanges as an additional subscriber s line Operation based on interaction with the three range...

Page 5: ...re or insufficient range OC 50 mA R 1 T 1 extension telephone line connection to the alarm control panel or to a telephone set IN1 IN4 inputs The FLT output is a generalized fault indicator It gets ac...

Page 6: ...Shown symbolically below are single cycles of various LED lighting modes with their meaning described The shaded fields meaning the LED on and the blank fields the LED off LED off module power off no...

Page 7: ...cinity of electrical installations since this may involve a risk of malfunctioning Pay special attention to how the cable is laid between the module and the telephone terminals of the alarm control pa...

Page 8: ...digits and special characters The phone number should be dialed just like from a cellular phone as required by the operator of the network into which the telephone is logged It is recommended that th...

Page 9: ...means of SMS short text messages The SATEL s STAM 1 monitoring station only supports from version 4 07 SMS monitoring related to the input status of the GSM module located on the site e g GSM 4S or GS...

Page 10: ...ext violation 4 seconds or 4 minutes Controlling the operation of inputs consists in bypassing and unbypassing their operation This control can be performed manually or remotely The manual bypassing o...

Page 11: ...ple recognizing the password loaded in the module by the function 82 Bypassing IN4 will bypass the supervision of input 4 The module acoustically acknowledges the execution of the function by audible...

Page 12: ...storation to normal status termination of violation of the input which is not bypassed The messages can be sent maximally to four telephone numbers The messaging can have a form of SMS message or CLIP...

Page 13: ...rom dialing the number The cellular phone user has an option to early reject the connection but if he carries out this action too early the module will repeat the call Answering the call either by the...

Page 14: ...alarm control panel and load appropriate text to be sent into the control panel memory The telephone number as programmed in the control panel must consist of 1 The pager station number preprogrammed...

Page 15: ...ow function 114 is programmed 3 The properly received number is acknowledged in the handset by two beeps generated by the module Lack of acknowledgement or a busy signal means a dialing error and then...

Page 16: ...inals When connected to the control panel telephone output the GSM LT 2 module will simulate the telephone monitoring station i e the control panel will dial the monitoring station telephone number st...

Page 17: ...the module to be programmed from a computer The program is designed for IBM PC AT compatible computers It works in any computer hardware configuration in the WINDOWS 9x ME 2000 XP Vista environment I...

Page 18: ...Open the window with module data by selecting File New device GSM4 LT module in the program menu see Fig 7 Figure 7 2 Enter the options of module communication settings by clicking on the icon or thro...

Page 19: ...test of the module with cable connected to RS port 12 1 1 GSM LT 2 Tab This tab allows the user to configure the basic working parameters of the module The values shown on Fig 9 are just an example B...

Page 20: ...e programmed they are not programmed by default Figure 11 shows a view of the GPRS tab The presented values are just examples Full configuration is only possible from a computer with DLOAD10 program i...

Page 21: ...st correspond to that defined in the monitoring station Station key a sequence of 1 to 12 alphanumeric characters digits letters and special characters which define the key for coding the data to be s...

Page 22: ...hrough GPRS RS 232 reporting priority if this option is selected monitoring the events of the control panel connected to the module through the RS 232 port will take priority over reporting the GSM LT...

Page 23: ...2 module programming mode This operation requires entering a six digit access code by default this code is 1 2 3 4 5 6 In case you have forgotten the code after the change you can only view it or rest...

Page 24: ...sword comprised of digits only 0 9 while using the DLOAD10 program you can program a password comprised of both letters and digits The 0 3 sequence deletes the previously programmed password 0 4 SMS p...

Page 25: ...is function is not used The 0 7 sequence will delete the number 0 8 modem standard format 2 digits the format in which the module will communicate with the modem of service user computer The format co...

Page 26: ...start after power up two short and one long SSL PH SIM PIN code required eight short SSSSSSSS no SIM card three long LLL SIM card damaged four beeps of diminishing length LlSs SIM card busy long short...

Page 27: ...0 test transmission priority This option determines whether the test transmission will override the call being just carried out by the module If yes the current connection will be terminated whenever...

Page 28: ...will change the parameter programmed with function 21 The new telephone number must be identical in form to that programmed with the appropriate function Using the DTMF signals you can program passwo...

Page 29: ...the module will automatically bypass input IN2 from 0 to 15 0 no bypassing 5 1 number of violations after which the module will automatically bypass input IN3 from 0 to 15 0 no bypassing 5 2 number of...

Page 30: ...fied The same settings as for input IN1 6 7 telephone numbers to which the input IN3 violation will be notified The same settings as for input IN1 6 8 telephone numbers to which the input IN4 violatio...

Page 31: ...messages of any content The sequence 8 1 will delete the SMS code 8 2 DTMF code 4 digits from the 0 9 range for bypassing the input IN1 The sequence 8 2 will delete the code 8 3 DTMF code 4 digits fro...

Page 32: ...1 Editing is similar as in function 06 The control is available after dialing the number which has been programmed here after which you should enter control sequences consisting of the character and...

Page 33: ...is to be sent as SMS message the number of digits must be within the range of 1 16 The sequence 1 0 7 will delete the number 1 0 8 telephone number to which SMS message whose content can only be enter...

Page 34: ...after the preprogrammed time from the settings being written to the module has elapsed 1 1 4 a country code prefix added before the cellular phone number to which SMS message is to be sent after recei...

Page 35: ...IMPORTANT PIN PUK Telephone No...

Page 36: ...SATEL sp z o o ul Schuberta 79 80 172 Gdansk POLAND tel 48 58 320 94 00 info satel pl www satel eu...

Reviews: