background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

COMMUNICATION MODULE 

GSM LT-2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

USER MANUAL 

Program version 2.12 

gsmLT-2_en 10/10 

 

®

Summary of Contents for GSM LT-2

Page 1: ...COMMUNICATION MODULE GSM LT 2 USER MANUAL Program version 2 12 gsmLT 2_en 10 10...

Page 2: ...tel 48 58 320 94 00 fax 48 58 320 94 01 Product description Communications module used to simulate PSTN line over GSM network allowing for alarm transmission in case of a failure or lack of telephone...

Page 3: ...THE INPUTS 8 9 MESSAGING 10 9 1 SMS MESSAGES 11 9 2 CLIP 11 10 TRANSMITTING SMS MESSAGES 12 10 1 DESCRIPTION OF THE PROCEDURE FOR CONVERTING PAGER MESSAGE INTO SMS MESSAGE 12 10 2 SENDING SMS MESSAGES...

Page 4: ...alarm control panel support of DLOAD64 GUARD64 DLOADX and GUARDX programs Operation with PBX telephone exchanges as an additional subscriber s line Operation based on interaction with the three range...

Page 5: ...re or insufficient range OC 50 mA R 1 T 1 extension telephone line connection to the alarm control panel or to a telephone set IN1 IN4 inputs The FLT output is a generalized fault indicator It gets ac...

Page 6: ...Shown symbolically below are single cycles of various LED lighting modes with their meaning described The shaded fields meaning the LED on and the blank fields the LED off LED off module power off no...

Page 7: ...cinity of electrical installations since this may involve a risk of malfunctioning Pay special attention to how the cable is laid between the module and the telephone terminals of the alarm control pa...

Page 8: ...digits and special characters The phone number should be dialed just like from a cellular phone as required by the operator of the network into which the telephone is logged It is recommended that th...

Page 9: ...means of SMS short text messages The SATEL s STAM 1 monitoring station only supports from version 4 07 SMS monitoring related to the input status of the GSM module located on the site e g GSM 4S or GS...

Page 10: ...ext violation 4 seconds or 4 minutes Controlling the operation of inputs consists in bypassing and unbypassing their operation This control can be performed manually or remotely The manual bypassing o...

Page 11: ...ple recognizing the password loaded in the module by the function 82 Bypassing IN4 will bypass the supervision of input 4 The module acoustically acknowledges the execution of the function by audible...

Page 12: ...storation to normal status termination of violation of the input which is not bypassed The messages can be sent maximally to four telephone numbers The messaging can have a form of SMS message or CLIP...

Page 13: ...rom dialing the number The cellular phone user has an option to early reject the connection but if he carries out this action too early the module will repeat the call Answering the call either by the...

Page 14: ...alarm control panel and load appropriate text to be sent into the control panel memory The telephone number as programmed in the control panel must consist of 1 The pager station number preprogrammed...

Page 15: ...ow function 114 is programmed 3 The properly received number is acknowledged in the handset by two beeps generated by the module Lack of acknowledgement or a busy signal means a dialing error and then...

Page 16: ...inals When connected to the control panel telephone output the GSM LT 2 module will simulate the telephone monitoring station i e the control panel will dial the monitoring station telephone number st...

Page 17: ...the module to be programmed from a computer The program is designed for IBM PC AT compatible computers It works in any computer hardware configuration in the WINDOWS 9x ME 2000 XP Vista environment I...

Page 18: ...Open the window with module data by selecting File New device GSM4 LT module in the program menu see Fig 7 Figure 7 2 Enter the options of module communication settings by clicking on the icon or thro...

Page 19: ...test of the module with cable connected to RS port 12 1 1 GSM LT 2 Tab This tab allows the user to configure the basic working parameters of the module The values shown on Fig 9 are just an example B...

Page 20: ...e programmed they are not programmed by default Figure 11 shows a view of the GPRS tab The presented values are just examples Full configuration is only possible from a computer with DLOAD10 program i...

Page 21: ...st correspond to that defined in the monitoring station Station key a sequence of 1 to 12 alphanumeric characters digits letters and special characters which define the key for coding the data to be s...

Page 22: ...hrough GPRS RS 232 reporting priority if this option is selected monitoring the events of the control panel connected to the module through the RS 232 port will take priority over reporting the GSM LT...

Page 23: ...2 module programming mode This operation requires entering a six digit access code by default this code is 1 2 3 4 5 6 In case you have forgotten the code after the change you can only view it or rest...

Page 24: ...sword comprised of digits only 0 9 while using the DLOAD10 program you can program a password comprised of both letters and digits The 0 3 sequence deletes the previously programmed password 0 4 SMS p...

Page 25: ...is function is not used The 0 7 sequence will delete the number 0 8 modem standard format 2 digits the format in which the module will communicate with the modem of service user computer The format co...

Page 26: ...start after power up two short and one long SSL PH SIM PIN code required eight short SSSSSSSS no SIM card three long LLL SIM card damaged four beeps of diminishing length LlSs SIM card busy long short...

Page 27: ...0 test transmission priority This option determines whether the test transmission will override the call being just carried out by the module If yes the current connection will be terminated whenever...

Page 28: ...will change the parameter programmed with function 21 The new telephone number must be identical in form to that programmed with the appropriate function Using the DTMF signals you can program passwo...

Page 29: ...the module will automatically bypass input IN2 from 0 to 15 0 no bypassing 5 1 number of violations after which the module will automatically bypass input IN3 from 0 to 15 0 no bypassing 5 2 number of...

Page 30: ...fied The same settings as for input IN1 6 7 telephone numbers to which the input IN3 violation will be notified The same settings as for input IN1 6 8 telephone numbers to which the input IN4 violatio...

Page 31: ...messages of any content The sequence 8 1 will delete the SMS code 8 2 DTMF code 4 digits from the 0 9 range for bypassing the input IN1 The sequence 8 2 will delete the code 8 3 DTMF code 4 digits fro...

Page 32: ...1 Editing is similar as in function 06 The control is available after dialing the number which has been programmed here after which you should enter control sequences consisting of the character and...

Page 33: ...is to be sent as SMS message the number of digits must be within the range of 1 16 The sequence 1 0 7 will delete the number 1 0 8 telephone number to which SMS message whose content can only be enter...

Page 34: ...after the preprogrammed time from the settings being written to the module has elapsed 1 1 4 a country code prefix added before the cellular phone number to which SMS message is to be sent after recei...

Page 35: ...IMPORTANT PIN PUK Telephone No...

Page 36: ...SATEL sp z o o ul Schuberta 79 80 172 Gdansk POLAND tel 48 58 320 94 00 info satel pl www satel eu...