SATEL GPRS-T4
23
– enter the GPRS key.
3. Define the protocol to be used by the module for sending event codes to the monitoring
station ("TCP/IP" and "UDP" fields).
4. Determine the operation mode for the inputs, the status of which is to be monitored
("Inputs" tab):
– define the input type (digital of NO or NC type or analog);
– define the "Sensitivity" and "Restore" parameters for the inputs (for the AC input only
the "Sensitivity" parameter);
– define additionally the "L threshold", "H threshold" and "Tolerance" parameters for the
analog inputs.
5. Define the status of which inputs and how is to be monitored ("Reporting" tab):
– indicate the monitoring station to which the event code is to be sent;
– program the event code which is to be sent;
– enter the partition number which will be sent in the event code;
– enter the zone / module / user number which will be sent in the event code.
4.6 Starting SMS reporting
1. Enter the telephone number of Short Message Service Center in the "SMS center
number" field in the "GSM telephone, Monitoring stations" tab, unless written by the
operator in the SIM card memory.
2. Configure
parameters
of the monitoring station(s) ("GSM telephone, Monitoring stations"
tab):
– select the "SMS" field;
– enter the GSM telephone number through which the monitoring station receives SMS
messages ("Tel. number (SMS)" field).
3. Define the SMS message format in which the received event codes will be sent to the
monitoring station ("GSM telephone, Monitoring stations" tab).
4. Define the operation manner for the inputs, the status of which is to be monitored
("Inputs" tab):
– define the input type (digital of NO or NC type, or analog);
– define the "Sensitivity" and "Restore" parameters for the inputs (for the AC input only
the "Sensitivity" parameter);
– for the analog inputs, define additionally the "L threshold", "H threshold" and
"Tolerance" parameters.
5. Define the status of which inputs and how is to be monitored ("Reporting" tab):
– indicate the monitoring station to which the event code is to be sent;
– program the required parameters (event code, partition code, number of zone / module /
user).
4.7 Starting CLIP / SMS messaging
The SMS or CLIP messaging is conducted irrespective of the monitoring.
1. Enter the telephone number of Short Message Service Center in the "SMS center
number" field in the "GSM telephone, Monitoring stations" tab, unless written by the
operator in the SIM card memory.
2. Enter the telephone numbers which are to be notified by the module, using the SMS
messages or CLIP service ("Telephone numbers for messaging and test transmissions"
table in the "GSM telephone, Monitoring stations" tab).