background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

GPRS/SMS Reporting Module 

GPRS-T4 

 
 
 
 
 
 

 

 

Program version 3.01 

gprs-t4_en 10/13 

 
 
 

SATEL sp. z o.o. 

ul. Schuberta 79 

80-172 Gda

ń

sk 

POLAND 

tel. + 48 58 320 94 00 

[email protected] 

www.satel.eu 

 

Summary of Contents for GPRS-T4

Page 1: ...GPRS SMS Reporting Module GPRS T4 Program version 3 01 gprs t4_en 10 13 SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel eu...

Page 2: ...iff plan providing for at least 10 MB monthly data transfer SATEL s goal is to continually improve the quality of its products which may result in alterations of their technical specifications and fir...

Page 3: ...sent in the form of GPRS transmission or SMS messages Using the GPRS technology makes it possible to send the codes to the STAM 2 monitoring station or SMET 256 converter The codes in SMS format can b...

Page 4: ...nsmissions after identification of the calling party s telephone number CLIP service after receiving command from the GPRS SOFT program Option to check the status of available resources and account va...

Page 5: ...king when GPRS transmission is going on LED B is blinking when SMS message is being sent or the module is calling CLIP test transmission the other LEDs indicate the level of signal received by the GSM...

Page 6: ...Be careful not to damage the socket 2 Connect the devices whose operation is to be monitored by the module to the input terminals as required 3 Connect the wire of transformer secondary winding from w...

Page 7: ...SATEL GPRS T4 5 Fig 4 Example of connecting power supply and testing AC voltage presence in GPRS T4 module 1 transformer 2 power supply unit 3 GPRS T4 module Fig 5 Installing the SIM card...

Page 8: ...th factory default settings can only be programmed locally Provision is also made for programming some parameters of the module by means of SMS messages 4 1 Local programming through RS 232 TTL port T...

Page 9: ...in the window that will open enter the number of TCP port selected for communication with the module The number will have to be included in the body of SMS message which will be sent to the module GS...

Page 10: ...en a window indicating the server status The button color indicates the current communication status green computer COM port enabled server active yellow data transfer in progress gray computer COM po...

Page 11: ...on between the program and the module is only possible when the identifier entered in this field is consistent with that stored in the module No identifier is preprogrammed in the module with factory...

Page 12: ...S SOFT program has been entered as a name If all addresses are given in the IP address form 4 decimal numbers separated by dots programming the DNS server address is not required Other USSD codes forw...

Page 13: ...ll be effected The port number must be the same as that programmed in the monitoring station Station key enter in this field a string of 1 to 12 alphanumeric characters digits letters and special char...

Page 14: ...ns may be sent periodically at defined time intervals and also can be generated after identification of the telephone number of the calling party CLIP service or after receiving a command from the GPR...

Page 15: ...enote new restore arming click on the field twice to select deselect it Part enter in this field the partition number which will be included in the event message sent to the monitoring station Zone n...

Page 16: ...he CLIP service In order to acknowledge receiving the CLIP test transmission reject the call coming from the module Retries number if the Acknowledgement field is selected the test transmission with t...

Page 17: ...evice status for the numbers in the list they will be sent by the module immediately for the numbers not in the list they can be sent by the module every 10 minutes at the most Control SMS messages ca...

Page 18: ...em with logging into the GSM network can be caused by missing SIM card entering a wrong PIN code missing or damaged antenna unavailable GSM network out of range telephone damage Additional information...

Page 19: ...shold the upper voltage threshold for analog input If the voltage rises above the defined value plus tolerance the module will register input violation Entering value 0 means that the voltage threshol...

Page 20: ...the functions of block unblock the inputs may contain up to 24 characters 4 3 5 CLIP SMS messaging tab Notification can be effected by means of SMS messages or by using the CLIP service the module doe...

Page 21: ...is to be sent to the monitoring station S1 select this field if the event code is to be sent to the monitoring station 1 S2 select this field if the event code is to be sent to the monitoring station...

Page 22: ...eld is also the button which enables opening of the code editor For the analog inputs the reporting related parameters are to be determined separately for each of the defined thresholds 4 3 7 Tel numb...

Page 23: ...update process Server address in SMS if this option is enabled you can enter the address of server to which the module is to connect and the port number in the content of SMS initiating the connection...

Page 24: ...ne number T3 DEL4 to delete the phone number T4 3 Delete all phone numbers from the Telephone numbers for messaging and test transmissions list sending DELALL 4 Reset the number of transmissions sent...

Page 25: ...S field enter the GSM telephone number through which the monitoring station receives SMS messages Tel number SMS field 3 Define the SMS message format in which the received event codes will be sent to...

Page 26: ...containing the control command to initiate the process of module firmware update SMS initiating update Firmware update tab to the module telephone number The module will connect to the firmware updat...

Page 27: ...S format Event Test transmission Control tab CLIP Reaction to CLIP only when number is on list of tel for messaging the option is enabled Control SMS control only from list of tel numbers for messagin...

Page 28: ...26 GPRS T4 SATEL OC outputs rating 50 mA 12 V DC Environmental class II Working temperature range 10 55 C Electronics board dimensions 80 x 57 mm Weight 184 g...

Reviews: