background image

®

 

Ethernet Module 

ETHM-1

 

ethm1_e 05/07 

The ETHM-1 Ethernet Module is a TCP/IP server. It enables the INTEGRA series control 
panels (program version 1.03 or later) to be operated via the Ethernet network. Data 
transmission in the network is coded by means of an advanced algorithm based on 192-bit 
key. The control panels can be operated via the Ethernet network with the use of PC 
computers or mobile phones. 
When using the computer, the control panel can be operated from the D

LOAD

X service 

program, G

UARD

X administrator program, as well as an Internet browser supporting the J

AVA

 

applications. The mobile phone uses a special J

AVA

 application to operate the control panel. 

Note:

 The module enables only one user to be connected at a time. The next users will 

receive a message on busy status of the server. 

The module with firmware version 1.02 or later provides an option for the INTEGRA series 
control panels (program version 1.04 and next) to perform monitoring via the Ethernet 
network. 
This manual refers to the ETHM-1 module with firmware version 1.02. Replacement of the 
module firmware is possible by means of the EthmFlash program, available on the website 
www.satel.pl 

1.  Description of electronics board 

 

 

Fig. 1. Schematic view of electronics board of ETHM-1 Ethernet module. 

Legend: 
1 – 

RS-232

 

port 

– enables the module to be connected to the control panel RS-232 port, so 

that the panel can be controlled via the Ethernet by means of the D

LOAD

X program. 

Additionally, it makes possible to replace the module firmware. Connect the port to the 

Summary of Contents for ETHM-1

Page 1: ...l Note The module enables only one user to be connected at a time The next users will receive a message on busy status of the server The module with firmware version 1 02 or later provides an option f...

Page 2: ...ion rate in the network 10Mb 100Mb Description of terminals 12V supply voltage input COM common ground TMP input of module tamper circuit NC connects the housing tamper contact if not used it should b...

Page 3: ...o be operated via the network by means of the DLOADX program connect the RS 232 ports of module and control panel with a cable made according to Fig 2 Fig 2 Connecting the RS 232 ports of control pane...

Page 4: ...ct the cable connecting the RS 232 ports of module and panel and then connect the cable connecting the computer and the panel to the control panel RS 232 port Note To obtain the network configuration...

Page 5: ...web server a different value must be entered If the entered value is different from 80 then when typing in the IP address of the ETHM 1 module in the browser insert a colon and the port number at the...

Page 6: ...ogram the control panel via Ethernet using the DLOADX program you should 1 Launch the DLOADX program on the computer which is to communicate with the module over the Ethernet the current DLOADX progra...

Page 7: ...le via Ethernet you can download the current GUARDX program from the website www satel pl 2 The program window will appear Select TCP IP connection in the Connection field 3 Press the Configuration bu...

Page 8: ...al Machine be installed on the computer The program can be downloaded from the website www sun com In order to operate the alarm control panel via Ethernet by means of the website JAVA application you...

Page 9: ...in button 4 A virtual keypad will appear in the window thus allowing you to operate the control panel similarly as with the LCD keypad You can use the LCD keypad either by means of your mouse or by pr...

Page 10: ...with JAVA application key identical to that programmed in the module for communication with JAVA application Note After three following connection attempts using an incorrect key the module will bloc...

Page 11: ...iew of the cellular phone with JAVA application running 10 Technical data Rated supply voltage 12V DC 15 Average current consumption 112mA Operating temperature range 0 55 C Electronics board dimensio...

Page 12: ...est EC declaration of conformity and certificates are available for downloading on our website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www sa...