Partition keypad 

CA-64 S   SATEL 

 

events from being entered several times into the control panel memory. This option 
allows the blocking function to be disabled. 

  Confirming – option determining the way of control panel communication with the partition 

keypad user:  

ƒ

  No – function of option confirming on keypad disabled 

ƒ

  Sound – the partition keypad generates the sounds described above in this manual, 

section “SIGNALLING”.  

ƒ

  Backlight – key backlit blinking is used instead of audible signalling, as described in this 

manual section “SIGNALLING”.     

  Backlight – defines the way of operation of key backlit:  

ƒ

  No – key backlit is off.  

ƒ

  Auto – key backlit is switched on automatically after pressing any key, this function has 

additional options:  

à

  No – key backlit is switched on only after pressing any key,  

à

  Zone violation: - key backlit is switched on also when the zone with the number 

entered in the field next to the option name has been violated,  

à

  Entry delay, part.: - key backlit is also switched on when the entry delay counting 

down is started in the partition with the number entered in the field next to the option 
name.  

NOTE:    Automatic keypad backlit is active for approximately 40 seconds, counting from 

the moment of its activation or from the last pressing of any key.  

ƒ

  Permanent - key backlit is switched on permanently.  

TECHNICAL DATA  

Supply voltage  ............................................................................................. DC 10,5V...14V 
Maximum current consumption   .................................................................................. 50mA 
Maximum voltage switched over by the relay  ................................................................. 24V 
Maximum current switched over by the relay .................................................................... 2A 
Dimensions .................................................................................................. 80x145x26 mm 

 

 

Latest EC declaration of conformity and product approval certificates can 

be downloaded from our Web site   www.satel.pl 

 

 
 
 
 
 

SATEL sp. z o.o. 

ul. Schuberta 79 

80-

172 Gda

ń

sk

 

POLAND 

tel. + 48 58 320 94 00 

[email protected] 

www.satel.pl 

 

Summary of Contents for CA-64 S

Page 1: ...ms that the partition assigned to this partition keypad is armed The LED blinks when the delay time is counted down TROUBLE yellow the LED blinks when technical problem has been detected in the system Check LCD keypad for a kind of trouble Indication of this LED relates to the entire system not only the partition operated with this partition keypad When this partition is armed the LED goes off and...

Page 2: ...ause disarming and operation of the relay only if the partition isn t temporary bypassed and the user has the right to disarm and use this keypad There is a possibility to control various equipment with the control panel for example switching off the lighting starting air conditioning etc The installer should inform the user which equipment may be operated by means of the given keypad Control func...

Page 3: ... user who enters his code now or end of code validity period Four short beeps and one long beep acceptance of execution of function selected code change done confirmation of a guard round Five short beeps dependent door open the relay has not been activated In order to activate the relay close the dependent door and enter code again Flashing of key lighting may be arranged instead of audible signa...

Page 4: ...ou start to wire the module to the existing alarm system 1 Remove the plastic module casing by pressing the clips which fix the casing bottom 2 Fix the bottom of plastic casing to the wall The connecting leads should be passed through the rectangular opening in this part of casing 3 Connect the leads of first or second expander bus to the following terminals DTA CLK and COM first bus CK1 DT1 COM s...

Page 5: ...tion process the control panel saves into memory the special number 16 bits which is used for checking the presence of the module in the system Replacement of the module with another one even if the same address is set without carrying out the identification process again causes alarm module tamper verification error 4 Program the partition keypad functions and define users authorised to use this ...

Page 6: ...F if door open The relay is active until the door is open input IN is disconnected from ground but no longer than for the Relay ON time Fixed ON time OFF if door closed The relay is active for the duration of door opening input IN disconnected from ground and it is de activated when the door is closed input IN is connected to ground again but the relay is active no longer than the Lock ON time Rel...

Page 7: ...tition keypad does not trigger an audible alarm but a message is transmitted to the monitoring station only and the input type 12 silent alarm is activated Figure 4 Changing access code When this option is marked the user code change function is accessible Quick arming Arming by pressing the keys 0 and in sequence Control BI output This option allows the partition keypad to accept the code for whi...

Page 8: ...fter pressing any key à Zone violation key backlit is switched on also when the zone with the number entered in the field next to the option name has been violated à Entry delay part key backlit is also switched on when the entry delay counting down is started in the partition with the number entered in the field next to the option name NOTE Automatic keypad backlit is active for approximately 40 ...

Reviews: