SATEL CA-64
O
3
2. Installation and start-up
All connections should only be made when power supply of the alarm system is
disconnected.
1. Install the expander electronics board in the enclosure.
2. Using the DIP-switches, set the expander address.
3. Using cables, connect the CLK, DTA and COM terminals to the corresponding terminals
of the control panel communication bus.
4. Connect the cables of enclosure tamper contact to the TMP and COM terminals (or short
the TMP terminal to the COM terminal).
5. Connect the cables of the devices whose operation is to be controlled by the control
panel, to the selected output terminals.
6. Connect the module power supply cables to the +12V and COM terminals. Supply may be
provided from the control panel mainboard, from an additional power supply unit or from
an expander with power supply (see: installer manual for alarm control panel).
7. Turn on power supply of the alarm system.
8. Start the identification function in the control panel. When the identification is completed,
the outputs will be assigned respective numbers in the alarm system (output numeration
rules are described in the alarm control panel manual).
3. Technical data
Supply voltage ................................................................................................... 12 V DC ±15%
Number of programmable outputs ........................................................................................... 8
Current consumption (without OC type output load and without active relays) ................36 mA
Current consumption by active relay................................................................................20 mA
OC-type programmable output maximum load ................................................................50 mA
Maximum relay switching voltage .......................................................................................24 V
Maximum relay switching current..........................................................................................2 A
Dimensions of electronics board............................................................................. 68x140 mm
Environmental class................................................................................................................. II
Working temperature range .............................................................................. -10 °C…+55 °C
Weight CA-64
O-OC.......................................................................................... 74 g
CA-64
O-R .......................................................................................... 118 g
CA-64
O-ROC ....................................................................................... 96 g