Satel CA-64 O-OC Manual Download Page 1

®

 

OUTPUT EXPANDER 

CA-64 O-OC 

CA-64 O-R 

CA-64 O-ROC

 

ca64o_en 03/09 

The CA-64 O output expander is designed for operation in intruder alarm systems. It is 
capable of interfacing with the SATEL made CA-64, INTEGRA and VERSA control panels. 
The device enables expansion of the system by 8 programmable outputs. It comes in three 
versions: 

  CA-64 O-OC – 8 OC type outputs; 

  CA-64 O-R – 8 relay outputs; 

  CA-64 O-ROC – 4 OC type outputs and 4 relay outputs. 

1.  Description of electronics board 

 

C1

NO1 NC1 C2 NO2 NC2 C3 NO3 NC3 C4 NO4 NC4 C5 NO5 NC5 C6 NO6 NC6 C7 NO7 NC7 C8 NO8 NC8

CLK

AUX

AUX

COM

TMP

COM

DTA

+12V

+12V

A D R E S
1 2 3 4 5

 

Fig. 1. View of the CA-64 O-R expander electronics board. 

 
Explanations for Fig. 1: 
1  - a set of DIP-switches for setting individual address of the module (see section 

DIP-

SWITCHES

). 

2  -  LED indicating communication with the control panel: 

  LED is blinking – data exchange with the control panel; 

  LED is lit – no communication with the control panel. 

3  -  LED indicating status of the outputs: 

  OC type output: LED is ON – output shorted to ground; 

  OC type output: LED is OFF – output disconnected from ground; 

Summary of Contents for CA-64 O-OC

Page 1: ...ription of electronics board C1 NO1 NC1 C2 NO2 NC2 C3 NO3 NC3 C4 NO4 NC4 C5 NO5 NC5 C6 NO6 NC6 C7 NO7 NC7 C8 NO8 NC8 CLK AUX AUX COM TMP COM DTA 12V 12V ADRES 12345 Fig 1 View of the CA 64 O R expander electronics board Explanations for Fig 1 1 a set of DIP switches for setting individual address of the module see section DIP SWITCHES 2 LED indicating communication with the control panel LED is bl...

Page 2: ...or in case of reversed polarization it is disconnected from the common terminal AUX power supply output 12V DC COM common ground TMP tamper input if no tamper contact is connected to this terminal it should be shorted to common ground CLK clock DTA data 12V power supply input The RESET pins are used during the manufacturing process hence they must not be shorted 1 1 DIP switches The DIP switches f...

Page 3: ...ed from the control panel mainboard from an additional power supply unit or from an expander with power supply see installer manual for alarm control panel 7 Turn on power supply of the alarm system 8 Start the identification function in the control panel When the identification is completed the outputs will be assigned respective numbers in the alarm system output numeration rules are described i...

Page 4: ...latest EC declaration of conformity and product approval certificates are available for downloading on website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gdańsk POLAND tel 48 58 320 94 00 info satel pl www satel pl ...

Reviews: