4. Configuring the LED indicator settings
You can configure the LED indicator by using the button on the plug enclosure. The LED
indicator can:
indicate the current consumption by the appliance when it is turned on:
– the indicator color changes smoothly from blue to green – current consumption by
appliances up to 300 W (current consumption up to 1.3 A), where: blue
– minimum
current consumption, green
– maximum current consumption,
– the indicator color changes smoothly from blue to red – current consumption by
appliances up to 2300 W (current consumption up to 10 A), where: blue
– minimum
current consumption, red
– maximum current consumption,
emit steady light when the appliance is turned on (you can select the color),
be turned off.
Starting configuration mode
Press and hold the button on the plug enclosure. Then connect the plug to the 230 VAC
socket and release the button after 3 seconds. When the configuration mode is started,
the LED indicator will turn ON, changing its color smoothly from blue to red
(see
“Configuring”).
Configuring
1. Keep pressing the button on the plug enclosure to select the indication mode. The LED
indicator shows which indication mode is currently selected:
– smoothly changes color from blue to red – the indicator will show the current
consumption by the appliance,
– flashing one color – the indicator will emit steady light when the appliance is turned on
(7 colors are available),
– OFF – the indicator will be turned off (only warm-up and troubles will be indicated).
2. Wait about 6 seconds. The selected indication mode is saved. The LED indicator
configuration mode is terminated.
5. Specifications
Operating frequency band ...............................
868.0 MHz ÷ 868.6 MHz / 915 MHz – 928 MHz
Radio communication range (in open area)
ABAX 2 ......................................................................................................... up to 1000 m
ABAX .............................................................................................................. up to 500 m
Supply voltage ............................................................................................ 230 VAC, 50-60 Hz
Standby power consumption ................................................................................................ 1 W
Rated current (resistive load) .............................................................................................. 10 A
For load other than resistive, it should not exceed 3 A at 230 VAC. The power factor
(cosφ) must be equal to or greater than 0.4.
Complied with standards .................................................................... EN 50130-4, EN 50130-5
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range ............................................................................... -
10°C...+55°C
Maximum humidity .......................................................................................................... 93
±
3%