background image

SATEL 

ASW-200 

4.  Configuring the LED indicator settings 

You  can  configure  the  LED  indicator  by  using  the  button  on  the  plug  enclosure.  The  LED 
indicator can: 

  indicate the current consumption by the appliance when it is turned on: 

–  the  indicator  color  changes  smoothly  from  blue  to  green  –  current  consumption  by 

appliances  up  to  300  W  (current  consumption  up  to  1.3  A),  where:  blue 

–  minimum 

current consumption, green 

– maximum current consumption, 

–  the  indicator  color  changes  smoothly  from  blue  to  red  –  current  consumption  by 

appliances  up  to  2300  W  (current  consumption  up  to  10  A),  where:  blue 

–  minimum 

current consumption, red 

– maximum current consumption, 

  emit steady light when the appliance is turned on (you can select the color), 

  be turned off. 

Starting configuration mode 

Press  and  hold  the  button  on  the  plug  enclosure.  Then  connect  the  plug  to  the  230  VAC 
socket  and  release  the  button  after  3  seconds.  When  the  configuration  mode  is  started, 
the LED  indicator  will  turn  ON,  changing  its  color  smoothly  from  blue  to  red 
(see 

“Configuring”). 

Configuring 

1.  Keep pressing  the  button  on  the  plug  enclosure  to  select  the  indication mode.  The  LED 

indicator shows which indication mode is currently selected: 
–  smoothly  changes  color  from  blue  to  red  –  the  indicator  will  show  the  current 

consumption by the appliance, 

–  flashing one color – the indicator will emit steady light when the appliance is turned on 

(7 colors are available), 

–  OFF – the indicator will be turned off (only warm-up and troubles will be indicated). 

2.  Wait  about  6  seconds.  The  selected  indication  mode  is  saved.  The  LED  indicator 

configuration mode is terminated. 

5.  Specifications 

Operating frequency band ............................... 

868.0 MHz ÷ 868.6 MHz / 915 MHz – 928 MHz 

Radio communication range (in open area) 

ABAX 2 ......................................................................................................... up to 1000 m 

ABAX .............................................................................................................. up to 500 m 

Supply voltage ............................................................................................ 230 VAC, 50-60 Hz 

Standby power consumption ................................................................................................ 1 W 

Rated current (resistive load) .............................................................................................. 10 A 

For load other than resistive, it should not exceed 3 A at 230 VAC. The power factor 
(cosφ) must be equal to or greater than 0.4. 

Complied with standards .................................................................... EN 50130-4, EN 50130-5 

Environmental class according to EN50130-5 ......................................................................... II 

Operating temperature range ............................................................................... -

10°C...+55°C 

Maximum humidity .......................................................................................................... 93

±

3% 

Summary of Contents for ASW-200

Page 1: ...ASW 200 Smart plug EN Firmware version 1 00 asw 200_en 11 21 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 20 www satel eu...

Page 2: ...rket after 13 August 2005 The device meets the technical regulations of the Eurasian Customs Union SATEL aims to continually improve the quality of its products which may result in changes in their te...

Page 3: ...iption 2 Radio communication 3 Operating modes 3 Protection against overload and overheating 3 LED indicator 4 3 Start up 4 4 Configuring the LED indicator settings 5 Starting configuration mode 5 Con...

Page 4: ...up to 2300 W Relay switched on when the voltage is at the zero cross point Encrypted two way radio communication in the 868 MHz 915 MHz frequency band AES standard Transmission channel diversity 4 cha...

Page 5: ...to turn ON OFF the appliance connected to the plug Information about the appliance state is sent to the controller control panel mode 2 remote or manual control but with option to manually block the r...

Page 6: ...icator is also used in the LED indicator configuration mode 3 Start up The ASW 200 plug should be used indoors in spaces with normal air humidity When in use the plug must be located within the radio...

Page 7: ...changing its color smoothly from blue to red see Configuring Configuring 1 Keep pressing the button on the plug enclosure to select the indication mode The LED indicator shows which indication mode i...

Page 8: ...6 ASW 200 SATEL Dimensions ASW 200 E 45 x 67 mm ASW 200 F 45 x 70 mm Weight ASW 200 E 60 g ASW 200 F 61 g...