1471
AMD-102
WIRELESS MAGNETIC CONTACT
WITH INPUT FOR ROLLER SHUTTER DETECTOR
amd102_en 11/16
The AMD-102 magnetic contact can detect opening of a door, window, etc. It is provided with two
additional inputs: one for roller shutter detector and one of NC type. The detector is designed for
use as part of the ABAX two-way wireless system. This manual applies to the magnetic contact
with firmware version 5.01, which is supported by:
ACU-120 / ACU-270 controller,
ACU-100 / ACU-250 controller with firmware version 4.03 2014-05-15 (or newer),
ARU-100 repeater with firmware version 2.00 2014-05-15 (or newer),
INTEGRA 128-WRL control panel with firmware version 1.12 2013-12-20 (or newer).
1. Features
Two reed switches allowing to select the magnet installation manner.
Input for connecting a hardwired roller shutter detector.
Input for connecting an NC type hardwired detector.
Remote
configuration.
LED indicator enabled in test mode.
Tamper protection against cover removal and tearing enclosure from the wall.
2. Specifications
Operating frequency band ......................................................................... 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area).................................................................. up to 500 m
NC type input sensitivity ...................................................................................................... 312 ms
Battery......................................................................................................................... CR123A 3 V
Battery life expectancy ............................................................................................approx. 3 years
Standby current consumption.................................................................................................50 µA
Maximum current consumption .............................................................................................16 mA
Complied with standards .... EN 50130-4, EN 50130-5, EN 50131-1, EN 50131-2-6, EN 50131-5-3
Security grade according to EN50131-2-6.......................................................................... Grade 2
Environmental class according to EN50130-5 ............................................................................... II
Operating temperature range .................................................................................. -10 °C...+55 °C
Maximum humidity ............................................................................................................... 93±3%
Detector enclosure dimensions ...........................................................................26 x 112 x 29 mm
Surface mounted magnet enclosure dimensions...................................................26 x 13 x 19 mm
Surface mounted magnet spacer dimensions.......................................................26 x 13 x 3.5 mm
Flush mounted magnet enclosure dimensions ......................................................28 x 10 x 10 mm
Weight ...................................................................................................................................... 76 g
Hereby, SATEL sp. z o.o., declares that this detector is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
The declaration of conformity may be consulted at www.satel.eu/ce