Adding, connecting the thermostats with the control centre 

The terminal strip can accept up to 8 different or the same wireless thermostats. The first one is always considered as 
Master and the others as Slaves. You can start adding thermostats by preparing the terminal strip the following way: 

Hold 

 button for 3 seconds while the terminal strip is powered on. On the LED display 

 the 

first indicator should turn red. You will always be pairing the thermostat regarding on which of the LED IDs is lit.  

The first indicator is always considered for a MASTER* thermostat. Others are meant as SLAVE** thermostats. You 

can move over the LED IDs from 1-8 by short pressing the 

 button while in connectivity mode. The first (1 - 

master) thermostat can control only the first heating circuit or all of the heating circuits, if master mode is activated. 
Other thermostats (2-8) are considered as slave thermostats and can control only their own heating circuits or none, if 
they are overridden by the master thermostat. 

So if you are in connectivity mode and you’ve selected the desired position for the thermostat (1-8), then you have to 
put your thermostat (Saswell T19WHB-7-RF, Saswell SAS908XWHB-7-DF, …) in connectivity mode and pair it. The 
connectivity process for the thermostats are different for each one, so be sure to read the manual of your thermostat. If 
the connection is successful, the selected LED should blink three times as a sign of confirmation of connectivity. When 
you’re done adding the first thermostat, continue adding the next ones with the same procedure. 

* Only SAS908XWHB has the function to be either a master or a slave. All other thermostats paired on the first position 
will be regarded as a master and override all other thermostats all the time. 
** All thermostats can work as slaves if there is no thermostat paired on position 1 or the SAS908XWHB is on position 
1 and is in ROOM CON mode.

 

Summary of Contents for SCU209DE

Page 1: ...1 SI Brez i na Centralna priklju na letev za talno ogrevanje ENG Wireless terminal strip centre for underfloor heating SASWELL SCU209DE Uporabni ki priro nik User manual...

Page 2: ...2 Compatible models T19WHB 7 DF SAS908XWHB 7 DF SAS816WHB 0 DF SAS918WHB 0 DF...

Page 3: ...etajlov tehnologije in izvedbe Garancija velja le skupaj z ra unom Dopu amo mo nost napak v besedilu Varovanje narave Elektronske naprave in baterije po koncu ivljenjske dobe ne odlagajte med me ane k...

Page 4: ...i gane sve ke ipd Izdelka ne postavljajte na mesta kjer ni zadostnega kro enja zraka V prezra evalne odprtine ne vtikajte nobenih predmetov Ne posegajte v notranjo elektri no napeljavo izdelka lahko g...

Page 5: ...vanja LED prikaz delovanja na izhodih Specifikacije enote Napajanje AC 100 240V 50 60Hz Temperatura okolice delovanja od 0 C do 50 C Skladi na temperatura od 10 C do 60 C Dimenzije 280x110x40mm Kontak...

Page 6: ...no pred samo nastavitvijo si zopet preberite vsa varnostna opozorila in izklopite glavno napajanje Po kon ani vezavi namestite zadnji del ohi ja s prilo enimi vijaki na eljeno mesto stena Ko ste oprav...

Page 7: ...klopov L Faza N Nula PE Ozemljitev RA1 do RA8 priklopi za posamezne termo glave oz upravljanje ogrevalnih vej prostorov Pump Priklop za obto no rpalko Boiler Brez napetostni kontakt za priklop ogreval...

Page 8: ...osvetli zeleno e je naprava pri gana oz ima napajanje se LED indikator osvetli rde e e na nobenem od izhodov od 1 5 ni potrebe po delovanju in so ugasnjeni se po ponovni potrebi delovanja ogrevalnega...

Page 9: ...a sedaj letev aka na paritev MASTER termostata za upravljanje prve ogrevalne zanke oz sobe ter ima tudi mo nost upravljanja vseh ogrevalnih vej e elite na kratko pritisnite tipko in boste pre li na t...

Page 10: ...rmance The guarantee is valid only with the original invoice We allow the possibility of errors in the text Environmental protection Do not place electronic products and batteries after the end of the...

Page 11: ...t place the product in places where there is insufficient air circulation Do not insert any objects into the ventilation openings Do not interfere with the internal electrical wiring of the product It...

Page 12: ...a 868MHz frequency Specifications Power supply 100 240V AC 50 60Hz Communication Wireless RF 868 MHz FSK half duplex RF range Up to 100m no obstacles Ambient temperature 0 C 50 C Transport and warehou...

Page 13: ...ns on the sides of the case and slowly remove the front part Now you have access to the electronic board Perform the electrical wiring by your needs and place the housing on the desired place on your...

Page 14: ...g description L Live N Neutral PE Grounding Earth RA1 do RA8 Connectors for each thermal actuators or heating zones Pump Connector for manifold pump Boiler Volt free contact for connecting a heating s...

Page 15: ...n there is a need for heating the indicator under the particular number 1 8 turns on green If the device is turned on or plugged in to power supply the LED indicator turns red If there is no output on...

Page 16: ...rmostats 2 8 are considered as slave thermostats and can control only their own heating circuits or none if they are overridden by the master thermostat So if you are in connectivity mode and you ve s...

Reviews: