6. Troubleshooting
7. Specification & Dimension
5. Pattern Setting
Adjust the scope of alert
When detection was not normal
Install at a different place or block the light
When it is exposed to direct ray of light or
Remove dirt with soft cloth
Dirt on the cover
The unit is improperly working
Check if the source is DC 8 ~ 18V.
Electricity source is not correct.
Check wiring connection
Broken wire or inner circuit is broken
No contact point when detected
Check wiring connection
Broken wire, LED or inner circuit is broken
LED is not working when detected
Check wiring connection
Broken wire or inner circuit is broken
No contact point although it is set
Check the wiring
Lines of electricity source are cut.
LED is not turned on
Solution
Cause
Symptoms
※
Pattern Setting Adjustment
Section
STEP
A (0
°)
B (12
°)
C (20
°
)
D (36
°
)
Installation Height
(2.5m)
12m
7m
3m
Lower than 2m
(back side 0.3m)
Model
PA-0112
Detection System
Passive Infrared motion detecting
Alert Range
3D Detection Alert Range: 12m
/ 84˚
Zone
17 Pairs (34 Zone)
Voltage
DC 8 ~18V
(Polarity)
Current
20mA (MAX)
Alarm output
Non-voltage contact point output (Select N.C / N.O)
Time of contact point : 2 sec
±
0.5 sec
Current : AC/DC 30V 0.2A Max
(Protection Resistance
: 18Ω)
Alarm LED(RED)
Blink when warming up / LED off when setting
/ LED on when detecting
Temperature
-20
℃
~ +60
℃
Installation
Indoor
Material
COVER, BASE: ABS Resin, LENS: PE Resin
Dimension
Φ131 x 48 mm
Weight
110g
Features
360˚ Rotation, Sensitivity Inhibition Control,
Temperature Indemnity, Back Side Detection
Φ131mm
4
8
m
m
A
A
D
※
Caution : This specification may be changed without prior notice for development