4 1-800-810-WIRE • www.sargentlock.com • A7856C
Profile Series v.G1.5 Rim Exit Device
Copyright © 2016, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/31/16
Specifications
3
Profile Series Rim Exit
• Latch – 3/4” throw, stainless steel
• Outside motor driven Exit Trim (“ET”) lever
controlled by keypad
• Push bar retracts latch from inside
• Fire stop provided on all lever handle designs
• Profile Series exit devices furnished for 1-3/4”
doors
• UL Listed
• Accepts all SARGENT rim cylinders (8877 only)
• Key retracts latch (8877 only)
• Available in ET lever handle designs only
Profile Series Mortise Exit
• Latch – 3/4” throw, anti-friction, brass
• Outside motor driven Exit Trim (“ET”) lever
controlled by keypad
• Push bar retracts latch from inside
• Fire stop provided on all lever handle designs
• Profile Series exit devices furnished for
1-3/4” doors
• UL Listed
• Accepts all SARGENT mortise cylinders (8977 only)
• Key retracts latch (8977 only)
• Available in ET lever handle designs only
General Description
2
Features
4
The SARGENT Profile v.G1.5 Rim and Mortise Exit Devices are designed for areas which require stand-alone
authorized entry. They consist of a self-contained microprocessor-controlled keypad with non-volatile memory.
The keypad holds a total of 100(LK)/2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) different user codes.
User codes
01 and 02 are utilized for Master and Supervisory Codes, respectively. SARGENT mortise locks are
designed with quality components to provide high security, performance and durability.
• The Profile v.G1.5 Series provides enhanced software and hardware features.
• New v.G1.5 controllers replace v.G1 controllers. Product is still ordered as “G1-” prefix.
Controllers are labeled “G1.5”.
• This product is operated by six (6) “AA”
alkaline
batteries.
• RF Fob and Proximity Card, Tag, and
Fob are optional
• Operates utilizing any one to six digit code.
• Digits may be repeated and codes may start
with zero
• Cylinder override
• Entry of three wrong User Codes disables all
codes for ten seconds. Yellow LED on solid
• Piezo horn can be heard with each keystroke or
turned off by Master or Supervisory Code
• Last 15 transactions can be output to portable
print via infrared link (LK Only)
• Last 2000 (Except LK) transactions can be
output to PC via SofLink™ Plus Software
• Non-volatile memory
• Motor driven, battery operated
• Battery operated with 6 “AA” Alkaline
• Low battery alert–4 chirps after code entry
• External remote “request to enter”
• Master, Emergency or Supervisory code will
unlock door when low battery has expired
• 100 (LK) or 2000 (G1-LU, G1-PK, G1-PA,
G1-TU, G1-TP, G1-TA) users
• Programming done at keypad or with a DTD
(Data Transfer Device) using SoloPlus™
software and a Laptop /PC (G1-TA and
G1-TP require software)
SoloPlus™ works with PalmPilot; SofLink™
Plus software not supported with DTD.
Summary of Contents for v.G1.5