Sargent EC325-PSU Manual Download Page 2

EC 325 Power Supply Details
For complete operation details refer to our Instruction 
& Specifications Manual available from Wirraway 
Motorhomes as a PDF document that will be emailed 
to you on request. Some of this information is 
included in the following text and illustrations, refer to 
instruction manual for full operating instructions.

3.1 Battery Charger
The EC325PSU incorporates an intelligent ‘offline’ 
battery charger that disconnects the leisure equipment 
from the battery while it is being charged. This process 
allows the charger to use higher charging voltages and 
to accurately control the charging current.
No other equipment may be connected directly to the 
battery while charging is taking place. This intelligent 
battery charger draws power from the power converter 
when the mains 230v supply is turned on and from 
the vehicle alternator when the engine is running, 
therefore the leisure battery is always charged via the 
intelligent battery charger. The charger can be preset 
at instillation for either Gel or Lead Acid batteries.  

The EC325 system also incorporates a battery 
compartment temperature sensor, which monitors the 
battery ambient temperature to allow the charger to 
adjust the charging current if the battery is very cold or 
hot to optimise performance.

3.2 Residual Current Device
      & Miniature Circuit Breakers
The Residual Current Device (RCD) is basically 
provided to protect the user from lethal electric shock. 
The RCD will turn off (trip) if the current flowing in the 
live conductor does not fully return down the neutral 
conductor, i.e. some current is passing through a 
person down to earth or through a faulty appliance.
To ensure the RCD is working correctly, the test button
should be operated each time the vehicle is connected 
to the mains supply.

The Miniature Circuit Breakers (MCB’s) operate in a 
similar way to traditional fuses and are provided to 
protect the wiring installation from overload or short 
circuit. If an overload occurs the MCB will switch off 
the supply. If this occurs you should investigate the 
cause of the fault before switching the MCB back on.

3.3 System Monitor

The system monitor circuit 

checks the power supply 

key components to ensure 

optimum operation. The 

current status is displayed 

on the front of the PSU 

by the means of a clear 

indication that illuminates in 

different colours depending 

on the PSU status.

 

                              EC325 Power Control System 

 

 

 

 

Issue 01B 

Page 3 of 16 

28 January 2007 

1  Template 

Instructions 

<<Delete before 

use>> 
 

3.2  Residual Current Device & Miniature Circuit Breakers 

 

The Residual Current Device (RCD) is basically provided 

to protect the user from lethal electric shock.  The RCD will 

turn off (trip) if the current flowing in the live conductor 

does not fully return down the neutral conductor, i.e. some 

current is passing through a person down to earth or 

through a faulty appliance.  
To ensure the RCD is working correctly, the test button 

should be operated each time the vehicle is connected to 

the mains supply (see section 5.1) 
The Miniature Circuit Breakers (MCB’s) operate in a similar 

way to traditional fuses and are provided to protect the 

wiring installation from overload or short circuit.  If an 

overload occurs the MCB will switch off the supply.  If this 

occurs you should investigate the cause of the fault before 

switching the MCB back on.

 

The following table shows the rating and circuit allocation for the three MCB’s 

MCB 

Rating 

Wire Colour 

Description 

10 Amps 

White 

230v Sockets 

10 Amps 

White (Yellow for heater) 

Extra 230v Sockets / Heater 

6 Amps 

Black (Blue for water heater) 

Fridge / Water Heater / 12v Charger 

(internally connected) 

3.3  System Monitor  

 

The system monitor circuit checks the power supply key components to ensure 

optimum operation.  The current status is displayed on the front of the PSU by 

the means of a clear indication that illuminates in different colours depending 

on the PSU status. 

 

Le

ft 

C

en

tre

 

R

ig

ht

 

Status 

Indication description 

-  G 

Good 

Mains supply on, PSU status good. 

Good 

Mains supply off, PSU status good. 

-  O  G 

Warning 

Mains supply on, PSU in warning mode.  In this mode the PSU will 

limit the output current to protect the unit from damage.  It is still safe 

to use the unit but the fault should be investigated. Typical causes are 

battery temperature sensor unplugged, cooling fan not working, 

internal sensors disconnected or failed. 

-  O  - 

Warning 

Mains supply off, PSU in warning mode.   

R  O  G 

Failure 

Mains supply on, PSU in overheat failure mode.  In this mode the PSU 

will shutdown and all equipment will be switched off.  The cooling fan 

will continue to run until the unit cools down.  Typical causes are short-

circuited DC output, battery connected in reverse, cooling fan failed, 

cooling vents blocked / covered, problem caused by prolonged use in 

warning mode. 

-  G 

Failure 

Mains supply on, PSU in overheat failure mode.   

R  O  - 

Failure 

Mains supply off, PSU in overheat failure mode.   

Test 

Button 

RCD 

MCB’s 

ECU325PSU_4PPBrochure_V3_b9022.indd   2

9/8/11   2:16:15 PM

Summary of Contents for EC325-PSU

Page 1: ...ery chargers Built in dual Solar Regulator Allows the direct connection of a 20 to 100W solar panel without the need for additional components The dual regulator charges both the vehicle and leisure batteries simultaneously System Monitor Circuit Monitors key components within the power supply to ensure optimum operation A simple traffic light indicator shows the power supply status Enhanced Digit...

Page 2: ... EC325 Power Control System Issue 01B Page 3 of 16 28 January 2007 1 Template Instructions Delete before use 3 2 Residual Current Device Miniature Circuit Breakers The Residual Current Device RCD is basically provided to protect the user from lethal electric shock The RCD will turn off trip if the current flowing in the live conductor does not fully return down the neutral conductor i e some curre...

Page 3: ...and therefore any equipment that was left switched on will be turned ON The 12v power will be switched OFF at Midnight 24 00 E C 32 5 P ower C ontrol S ys tem 1 Template Ins truction s Delete before use 4 Control Panel Details 4 1 Lay out and B uttons The following diagram shows the control panel layout and button functions Note to remove the decorative bezel pull down and lift forward as indicate...

Page 4: ...nector Fresh water negative sensed Waste water negative sensed Data IN O UT Data communication and power to Control Panel via 20 way IDC header connector IP rating IP31 Operating temperature Ambient 0 to 35 Centigrade PS U case temperature with full load 65 C Max Automatic shutdown and restart if overheated overloaded 6 2 Dimens ions Overall size HxW xD 240 x 370 x 110mm Fixing centres 210 x 360mm...

Reviews: