Time Lock Keypad (TLKP) Model 6120-420 for use with S&G lock models: 

2003 (Z

03

 Rotarybolt™), 6124, 6125, 6126 Audit Lock, and 6127 Audit Lock. 

 

General Information  

•  The TLKP is “digital” (not analog like other S&G e-locks). Input codes with a quick push. Holding down the button will give 
unsatisfactory results.  
•  Lock functions remain the same after installation of the Time Lock Keypad. Refer to the operating instructions packaged with 
the lock for programming and usage of lock functions. These instructions are for the Time Lock Keypad only. 
•  The TLKP factory default Master Program Code is: 0 0 1 2 3 4 5 6 # 

•  The TLKP factory default Program Code (also known as the Local Code) is: 1 2 3 4 5 6 # 

These are keypad codes, and are separate from any Master Code and/or Supervisor Code  
that may be present in the lock. 

•  To enter TLKP programming mode press 

.  When the time and date appear on the LCD, press and hold 

 until the 

LCD prompts you to enter a program code.  Enter the program code, followed by #. 
•  All codes and most data entries must be followed by pressing #. 
•  When options are available on the LCD, you can scroll through them using the 

 and   buttons. 

•  Pressing and holding 0z powers down the keypad.  
•  If you refrain from pressing any keypad buttons for approximately one minute, the keypad will power down. 
•  If 5 or more incorrect codes are entered in a row, the keypad will shut down for 15 minutes after displaying the “Penalty” 
message.  During this period, the keypad will not accept any code entries, and will display “Penalty” whenever code entry is 
attempted.  When 

 is pressed, the amount of penalty time remaining will be displayed.  Attempting to enter any code 

during the penalty time will cause the penalty timer to reset to the full 15-minute period. This is independent of any penalty time 
feature built into the lock. 

 

FUNCTIONS OF THE TIME LOCK KEYPAD 8-DIGIT TLKP MASTER PROGRAM CODE 
 

1. Select Language 

The Time Lock Keypad can display messages in English, Spanish, Portuguese, German, and Italian. 
To enter TLKP programming mode press 

.  When the time and date appear on the LCD, press and hold 

 until the LCD 

prompts you to enter a program code.  Enter the Master Program Code, followed by #. Scroll down until the language option is 
displayed (option 3).  Press 3, then scroll through the language options (using the 

 and   buttons) until you find the 

language you want.  Press the number button, which corresponds with the desired language. Wait for the keypad LCD to clear, 
or press 0z to back up to the previous menu. Optionally, you can press and hold 0z to power down the keypad. 
 

2. Set Daylight Saving Time (Summer/Winter Time) 

This feature must be set before setting the current time. 

 
To enter TLKP programming mode press 

.  When the time and date appear on the LCD, press and hold 

 until the LCD 

prompts you to enter a program code.  Enter the Master Program Code, followed by #.  
Option 1 is Keypad Setup.  Press 1.   
Scroll down to Summer/Winter (option 3).  Press 3.  

Enter the start date and the end date for Daylight Saving Time (Summer/Winter Time) for this year.  Enter dates in DD/MM 
format, followed by #.  

If Daylight Saving Time is not applicable to your location, enter 000000 for both the start and end dates.

 

Wait for the keypad LCD to clear, or press 0z to back up to the previous menu.  
Alternatively, you can press and hold 0z to power down the keypad. 

 

      

3. Set Time  

To enter TLKP programming mode press 

.  When the time and date appear on the LCD, press and hold 

 until the LCD 

prompts you to enter a program code.  Enter the Master Program Code, followed by #.  
Option 1 is Keypad Setup.  Press 1.  
Option 1 in the menu now displayed is Set Time.  Press 1.  
Enter the current time in 24-hour format (i.e. 3:20 p.m. is entered as 15:20) followed by #.  
Wait for the keypad LCD to clear, or press 0z to back up to the previous menu.  

Alternatively, you can press and hold 0z to power down the keypad. 

Summary of Contents for 6120-420

Page 1: ...ty time will cause the penalty timer to reset to the full 15 minute period This is independent of any penalty time feature built into the lock FUNCTIONS OF THE TIME LOCK KEYPAD 8 DIGIT TLKP MASTER PRO...

Page 2: ...s must be 00 When prompted to confirm the new programmer code enter it again followed by The new programmer code will take effect immediately Wait for the keypad LCD to clear or press 0z to back up to...

Page 3: ...wed by Option 1 is Keypad Setup Press 1 Scroll down to Serial Number option 5 Press 5 The keypad s serial number will be displayed It must match the serial number printed on the card inside the small...

Page 4: ...p to two different open periods per day and all times must be entered in 24 hour format 9 15 a m would be entered as 09 15 and 3 30 p m would be entered as 15 30 Four digits must be entered to success...

Page 5: ...e and date appear on the LCD press and hold until the LCD prompts you to enter a program code Enter the Master Program Code followed by Option 2 is Timelock Pr Press 2 In the resulting menu option 3 i...

Page 6: ...entered no holiday is scheduled If you set a value greater then five the TLKP will interpret your entry to be five days The screen will display Operation OK then revert to the main menu From the main...

Page 7: ...e 6 digit TLKP Program Local Code To enter TLKP programming mode press When the time and date appear on the LCD press and hold until the LCD prompts you to enter a program code Enter the 6 digit TLKP...

Reviews: