Frequently Asked Questions
Which systems do the Converter Box work with?
The Converter Box only works on 2-wire digital communication systems.
What voltage clocks can I use with the Converter Box?
The Converter Box only works on 24 volt clocks.
Can I use analog and digital clocks in conjunction with the Converter Box?
Yes, analog and digital clocks can be used with the Converter Box. Both the analog and the digital clocks must be 24 volts, and can accept the 2-
wire digital communication system. Please refer to the clock’s installation instructions for specific wiring diagrams.
What will happen if the polarity on the RS485 is reversed?
The clocks will power up, but not correct. Make sure the wires are on the correct polarity and/or refer to the wiring diagrams in the clock’s
installation manual.
What does the Load LED do?
The Load LED warns the user if the Converter Box is reaching 80% or higher of its maximum threshold of 5.5 amps. If the Load LED turns solid, it
will shut the Converter Box off, and will attempt to reset in two minutes.
What does the Temperature LED do?
The Temperature LED warns the user if the Converter Box is reaching 80% or higher of its maximum threshold for temperature. If the Temperature
LED turns solid, it will shut down the Converter Box, and will stay off until the user presses the reset button on the board.