25
The Sapling Company, Inc.
670 Louis Drive
Warminster, PA 18974
USA
P. (+1) 215.322.6063
F. (+1) 215.322.8498
www.sapling-inc.com
4
3
3) Depending on the clock model and accessories
that may have been purchased along with the
clock, additional wiring might need to be run to
the clock in order to interface with the accessory
(elapsed timer control panel, temperature sensor,
user input, etc.). For doing so, please review the
installation instructions and the wiring diagram for
your specific application (and/or accessory) which
can be found in this manual.
4) The next step would be to wire the clocks and
use the provided connectors attaching the to the
clock electric board.
Wiring the clock will depend on its designed
voltage input and type of wired system used (2-
wire, RS485 or 3-Wire Sync). Please refer to the
“
” section in this manual.
Uniform Stage Installation
5
5)
For flush mount installation:
Use the four (4) #6-32x1/2 flat head machine screws that are provided
with the clock to screw the display to the housing board.
For wall mount, double mount, or flag mount installation:
Use the four (4) #6-19x3/8 black flat
head thread-forming screws that are provided with the clock in order to screw the display board to the
clock housing.
NOTE:
For 2.5” Digital clocks, the holes for the screws will be on the left and right inner surfaces of the
housing. For 4.0” Digital Clocks, the holes will be on the top and bottom surfaces.
2.5”
4.0”