– 19 –
3-8. Adjust Specifications
1. Optical Axis Adjustment
Preparation:
POWER switch: ON
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set a distance of 1.0-3.0 cm between the camera lens and
the white part of fluorescent tube viewer.
(Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Input “251” to the “CalMode”, and click the OK.
4. Adjustment value will appear on the screen.
5. Click the OK.
2. Lens Adjustment (Infinity)
3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP1
Factory
Cord
Setting
Language
Setting
COMPL PWB VF1
COMPL PWB ST1
COMPL PWB TB1
Reset
Setting
COMPL PWB TB4
Lens
Adjust-
ment
(1 m)
AWB
Adjust-
ment
USB
storage
information
registration
CMOS
White Point
Defect
Detect
Adjustment
CMOS Black
Point And
White Point
Defect Detect
Adjustment
In Lighted
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
COMPL PWB TB2
COMPL PWB TB3
Lens
Adjust-
ment
(Infinity)
ASSY, FLEXIBLE PWB CA1
3-7. Updating the firmware
Check the firmware version immediately after the CP1 board has been replaced. If an old version is being used, interfer-
ence and errors in operation may also occur. If an old version is being used, update it with a newer version.
Refer to
3-13. Firmware uploading procedure. (Page 23)
Optical
Axis
Adjust-
ment
Camera
Collimator
Camera
1.0~3.0 cm
Fluorescent
tube viewer