2. Double-click on the DscCalDi127.
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
13. CCD Defect Detect Adjustment
Preparation:
POWER switch: ON (Set the camera mode.)
Adjustment method:
1. Double-click on the DscCalDi127.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
14. CCD Black Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that
nothing appears in any part of the color viewer except the
white section. (Do not enter any light.)
2. Double-click on the DscCalDi127.
3. Select “CCD Black” on the LCD “Test”, and click the “Yes”.
4. After the adjustment is completed, the number of defect will
appear.
15. LCD Panel Adjustment
[CA3 board (Side A)]
15-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi127.
2. Select 0 on the LCD “H AFC”.
3. Apply a trigger using CL407, and adjust LCD “H AFC” so
that the time A from the rising signal at CL407 to the fall-
ing signal at CL404 is 5.16
±
0.2 msec.
15-2. LCD RGB Offset Adjustment
Adjusting method:
1. Adjust LCD “RGB Offset” so that the amplitude of the CL402
waveform is 4.0 V
±
0.1 Vp-p.
Camera
0 - 18 cm
All white pattern
Color viewer
○○○○○○○
○
○○
A
CL404
CL407
Enlargement
○○○○○○○
○
○○
A
CL404
CL407
CL407
VR514
VR511
VR513
VR512
VR921
CL402(G)
CL403(R)
CL401(B)
CL404
(XENB)
CL572
TP921
TP922
C5133(+)
L1702
(input)
C5117(+)