– 18 –
3-8. Adjust Specifications
1. Lens Adjustment
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set a distance of 0.5-1.0 cm between edge of the camera
lens and edge of the collimator lens. Do not touch the each
lens.
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Click the Focus, and click the Yes.
5. Lens adjustment value will appear on the screen.
6. Click the OK.
Adjustment value determination is effectuated using the "STD_
AFPOS", "FOCUS", “LENS_ERR”, “IRIS_GAIN” and
“IRIS_OFFSET” values.
If FOCUS=focus1, focus2, focus3, focus4 and the adjustment
values fulfill the conditions below, they are determined as within
specifications.
3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP-1
Lens
Adjustment
AWB
Adjustment
CMOS White
Point Defect
Detect
Adjustment
CMOS Black
Point And White
Point Defect
Detect Adjust-
ment In Lighted
Factory
Cord
Setting
USB storage
information
registration
Language
Setting
COMPL PWB ST-1
COMPL PWB VF-1
Reset
Setting
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
LENS ASSY
ASSY FLEXIBLE PWB CA1
COMPL PWB TB-1
COMPL PWB TB-2
3-7. Updating the firmware
Check the firmware version immediately after the CP1 board has been replaced. If an old version is being used, interfer-
ence and errors in operation may also occur. If an old version is being used, update it with a newer version.
Refer to
3-13. Firmware uploading procedure. (Page 20)
Camera
Collimator
DscCalDi
x
OK
Focus Result
STD_AFPOS=1898
FOCUS=-10,-12,-11,-11
ADJ_PZPOS=0
LENS_ERR=0
IRIS_GAIN: 53
IRIS_OFFSET: 165
!