 6

 -

This section describes to adjust LCD monitor after replacing EEPROM, Main PBA or Panel.

2-1 Program Upgrade

Change MICOM

: If the similar happenings occur, EEPROM can be changed

-. EX1) When screen appears but remote control and function key aren't working 
-. EX2) When LED is on but the screen doesn't appear
-. EX3) After mass production, when the micom program version is up-graded

* MICOM replacement can be done when Service Bulletin issue is in practice. 

The process of working need to be prepare on Service Bulletin.

As the visual sample shown, after disassembling the set (refer to SET disassemble), remove the Micom in
the exist IC202 Socket and replace new Micom. 
- Use appropriate JIG or any sharp tool and place in the both corners to assist in removing. 

(Be aware! If the socket cause any damage after replacement the monitor will not function properly.) 

- When inserting, attend to IC No.1 direction and press with suitable amount of strength. 
- After replacement, in case of EEPROM Clear, enter to Factory mode and perform into action. 

2. ADJUSTMENT

Summary of Contents for VMC-L2017P

Page 1: ...ed to be replaced use only the part designated in the parts List Do not deviate from the specified resistance wattage and voltage ratings 3 Before returning the set to the customer always perform an AC leakage current check on the exposed metallic parts of the cabinet such as terminals screwheads metal overlays etc to be sure that the set is safe to operate without the danger of electrical shock P...

Page 2: ...ivalent and which lets you adjust the tip temperature up to 450 C 842 F It should also have as good temperature recovery characteristics as possible Set the temperature to 350 C 662 F or less for chip components to 380 C 716 F for lead wires and similar and to 420 C 788 F when installing and removing shield plates The tip of the soldering iron should have a C cut shape or a driver shape so that it...

Page 3: ...e sync Audio signal AUDIO IN 6 0 dBs 400 mVrms 2W 1W 1W stereo RCA pin x 2 VGA signal VGA IN VGA monitor connector 15 pin Red signal Green signal Blue signal 0 7 Vp p 75 ohms positive sync Output connector Video signal BNC OUT Composite sync signal 1 0 Vp p 75 ohms BNC connector x 2 S Video signal Y C OUT Separate Y C signal mini DIN connector Y signal 1 0 Vp p 75 ohms negative sync C signal 0 286...

Page 4: ...d lamp 7 Remove the assy chassis shield 8 Remove the assy LCD 9 Remove the glass protection 10 Assy cover P front 11 Remove the four screws 12 Remove the screw 13 Remove the two screws 14 Remove the IP board 15 Remove the MAIN board 16 Remove the screw 17 Remove the assy board P IR 18 Remove the assy board P function 4 3 5 6 7 8 9 10 1 2 BOARD LOCATION MAIN board Assy LCD IP board IR board FUNCTIO...

Page 5: ...e Bulletin issue is in practice The process of working need to be prepare on Service Bulletin As the visual sample shown after disassembling the set refer to SET disassemble remove the Micom in the exist IC202 Socket and replace new Micom Use appropriate JIG or any sharp tool and place in the both corners to assist in removing Be aware If the socket cause any damage after replacement the monitor w...

Page 6: ... 7 2 2 Factory Mode Adjustments 2 2 1 Factory Mode Admission 1 2 4 MENU 6 1 MUTE 8 2 Power on 2 2 2 Service Mode Menu DDP Part ...

Page 7: ... 8 MSTAR Part Adjust PC DTV Auto Color ...

Page 8: ... 9 Pre Setting Options Checksum Panel Information Reset ...