3-2
ELECTRICAL ADJUSTMENT PROCEDURES
1. Servo Adjustment
1) PG Adjustment
• Test Equipment
• Adjustment And Specification
a) OSCILLOSCOPE
b) PAL TEST TAPE (VHS SP)
MODE
PLAY
• Adjustment Procedure
a) Insert the PAL SP Test Tape and play.
Note - Adjust the distance of X, pressing the Tr) or Tracking(-) when the “ATR” is blink after the
PAL SP Test Tape is inserted.
b) Press the Auto PG KEY on JIG Remocon(1’st) or Press “REC” key on set and “CLEAR” key on
Remocon.(Then check the blink “TRK OK” on CLK/LED-TRK is a Initial)
c) Press the Auto PG Key on JIG Remocon again (2’nd) or press “REC” key on set and “CLEAR” key on
Remocon again.(Then check the blink “PG NG > PG OK” on CLK/LED.)
• Check the PG
a) Connect the CH1 of the oscilloscope to the H/SW and CH2 to the Video out for the VCR.
b) Trigger the mixed Video Signal of CH2 to the CH1 H/SW(W501, W502), and then check the distance
(time difference), which is from the selected A(B) Head point of the H/SW(W501, W502) signal to the
starting point of the vertical synchronized signal, to 6.5H ± 0.5H (416µs, 1H=64.0µs).
• CONNECTION
V.Out
H/SW(W501, W502)
6.5 ± 0.5H
MEASUREMENT POINT
ADJUSTMENT POINT
SPECIFICATION
V.Out
H/SW(W501,W502)
OSCILLOSCOPE
CH1 CH2
V.out
H/SW
(W501, W502)