− 8 −
Communications Protocol
[3] Command List for MD800-500
Message
System
All Initial
A0 01 0A CS FF
Initialization of Unadjusted EEPROM Values (Set to Factory Defaults)
All Menu Initial
A0 01 0B CS FF
Initialization of All Menu Settings
Lens Initial
A0 01 0C CS FF
Detection of initial lens position
Reset
A0 01 0D CS FF
Restarting camera (Saves the setting value)
Menu Initial
A0 01 0E CS FF
Initialization of menu settings other than privacy mask settings
Pixel defect compensation
A0 01 12 00 06 04 04 06 00 Applied version 1.21-** or later
(Note 8)
0C CS FF
Auto pixel defect
compensation at start-up.
A0 01 13 0p CS FF
p: 0:OFF Default , 1:ON
Applied version 1.21-** or later
※
Refer to "Communications Protocol [2]Communications Flow"
Zoom
Tele
A0 02 05 CS FF
Wide
A0 02 06 CS FF
Tele/Wide Stop
A0 02 07 CS FF
Tele/Wide Speed
A0 02 08 0p CS FF
p: Speed 1-4 during Tele and Wide commands (1: Slow-4: Fast [Initial value: 3])
Direct
A0 02 09 0p 0q 0r CS FF
pqr: Direct Position
・
MD800/700, 0: Wide, 2484: 36x (optical), 2724: 576x (digital)
・
MD600/500, 0: Wide, 2263: 30x (optical), 2503: 480x (digital)
Digital Zoom Tele Limiter command needs to be sent before moving to digital zoom field.
Zoom Direct with Focus
A0 02 0A 0p 0q 0r 0s 0t 0u pqr:Zoom Direct Position stu:Focus Direct Position
For carrying set the focus to the specified position.
CS FF
Digital Zoom Tele Limiter
A0 02 18 0p CS FF
p: Maximum digital zoom magnification (0: x0 [Initial value], 1: x2, 2: x4, 3: x8, 4: x16)
Optical Zoom Wide/Tele
Limitter
A0 02 19 xx yy CS FF
Wide/Tele Optical ZOOM Limiter The numbers within the brackets refer to the MD600/500 models
xx: 0, 1-35 [29] (0 is no limit and 1-35 [29] is the Wide optical ZOOM limit)
yy: 0, 2-36 [30] (0 is no limit and 2-36 [30] is the Tele optical ZOOM limit)
Note: Ensure that xx < yy
V-Reso.UP OFF/ON
A0 02 1F 0p CS FF
p: Increased vertical sensitivity settings during digital zoom OFF/ON (0: OFF, 1: ON)
(Note 3)
Zoom Preset ON
A0 02 28 CS FF
Moves the zoom position to the optical TELE edge
Zoom Preset OFF
A0 02 29 CS FF
Returns the zoom position to the position before the “Zoom Preset ON” operation
Focus
Auto Focus ON
A0 03 00 CS FF
Manual Focus ON
A0 03 01 CS FF
One Push Trigger
A0 03 03 CS FF
Operates the auto focus operation once
Far
A0 03 05 CS FF
Near
A0 03 06 CS FF
Far/Near Stop
A0 03 07 CS FF
Far/Near Speed
A0 03 08 0p CS FF
p: Speed 1-4 during Far and Near commands (1: Slow-4: Fast (Initial value: 2))
Direct
A0 03 09 0p 0q 0r CS FF
pqr: Direct Position (0: Far 1209: Near)
Near Limiter
A0 03 0E 0p CS FF
p: Subject distance limit during auto focus and manual focus
(0: 10 cm, 1: 30cm, 2: 50 cm, 3: 1 m [Initial value], 4: 3 m, 5: 5 m)
Auto Focus Sensitivity
A0 03 10 0p CS FF
p: Auto focus restart sensitivity settings (0: LOW/1: HI [Initial value])
Focus Area
A0 03 13 0p CS FF
Settings Determining Auto Focus Areas 1-3
1: Entire screen-3: Only center of the screen (Initial value: 2)
Cover Offset OFF/ON
A0 03 15 0p CS FF
p: Offset OFF/ON (0: OFF/1: ON) when using the cover
Cover Offset Level
A0 03 16 0p 0q CS FF
pq: Offset Level Setting 0 – 00 (Initial value: 5) when using the cover
Auto Focus Mode during pan/tilt A0 03 1F 0p CS FF
p: Auto Focus Mode Setting during Pan/Tilt (0: AF/1: Fixed)
White
Balance
ATW
A0 04 00 CS FF
Auto White Balance Mode (Same as "0" in WB Mode)
MWB
A0 04 01 CS FF
Manual White Balance Mode (Same as "2" in WB Mode)
One Push Trigger (AWC Set) A0 04 03 CS FF
Executes OnePush in AWC Mode
AWC Reset
A0 04 04 CS FF
Returns to the original mode only after executing the OnePush Trigger command
ATW Smart OFF/ON
A0 04 06 0p CS FF
Smart ATW (high color saturation compensation) ON/OFF (OFF: 0 [Initial value], ON: 1)
*This mode is valid when WB mode is set to ATW.
WB Mode
A0 04 07 0p CS FF
p: White Balance Mode 0-5
0: Auto White Balance, 1: AWC Mode (One-Push N/A), 2: Manual White Balance
3: 3200K Fixed Mode, 4: 5600K Fixed Mode, 5: FLUO Mode (4200K Fixed)
MWB Red +
A0 04 0B CS FF
MWB Red -
A0 04 0C CS FF
MWB Red Preset
A0 04 0F CS FF
Returns MWB red component settings to factory defaults (Initial value: 64)
MWB Red Direct
A0 04 13 0p 0q CS FF
pq: Direct MWB red components 0-255
MWB Blue +
A0 04 15 CS FF
MWB Blue -
A0 04 16 CS FF
MWB Blue Preset
A0 04 19 CS FF
Returns MWB blue component settings to factory defaults (Initial value: 64)
MWB Blue Direct
A0 04 1D 0p 0q CS FF
pq: Direct MWB blue components 0-255
ATW Masking OFF
A0 04 28 CS FF
Mask settings ON/OFF during ATW
ATW Masking ON
A0 04 29 CS FF
ATW Mask Area Clr
A0 04 2D CS FF
Initialization of mask settings during ATW
ATW Mask Area Set
A0 04 31 0p 0q 0r 0s 0t 0u Mask area settings during ATW
(Note 1)
0v 0w 0x 0y 0z 0n CS FF
ATW Mask Display
A0 04
32
0p CS FF
p: Displays the ATW MASK settings status on the monitor. (1: ON/0: OFF)
Iris
Auto IRIS
A0 05 00 CS FF
(Note 3)
Manual IRIS (EI OFF)
A0 05 01 CS FF
Manual IRIS (EI ON)
A0 05 02 CS FF
(Note 3)
Iris Level +
A0 05 0B CS FF
Iris level operation during auto iris
Iris Level -
A0 05 0C CS FF
Iris Level Preset
A0 05 0F CS FF
Returns iris levels during auto iris to factory defaults (Initial value: 40)
Iris Level Direct
A0 05 13 0p 0q CS FF
pq: Iris level 0 (Dark) - 100 (Bright) during auto iris (Initial value: 40)
Manual Iris Stop +
A0 05 15 CS FF
Aperture operation during manual iris (Initial value: 17)
Manual Iris Stop -
A0 05 16 CS FF
Manual Iris Stop Preset
A0 05 19 CS FF
Returns aperture during manual iris to factory default (Initial value: 17)
Manual Iris Stop Direct
A0 05 1D p
CS FF
p: Aperture 1 (Close) - 17 (Open) during manual iris
Model: VCC-MD800/700/600/500
CS: Checksum
FF: Terminator