13
-
Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
AF_I_WIDE: ZIW
ZIW: infinity adjustment value of focus at zoom position
wide (-126<=ZIW<=110)
AF_I_MID1: ZIM1
ZIM1: infinity adjustment value of focus at zoom position
middle1 (-138<=ZIM1<=121)
AF_I_MID2: ZIM2
ZIM2: infinity adjustment value of focus at zoom position
middle2 (-132<=ZIM2<=114)
AF_I_MID3: ZIM3
ZIM3: infinity adjustment value of focus at zoom position
middle3 (-128<=ZIM3<=209)
AF_I_MID4: ZIM4
ZIM4: infinity adjustment value of focus at zoom position
middle4 (-165<=ZIM4<=241)
AF_I_MID5: ZIM5
ZIM5: infinity adjustment value of focus at zoom position
middle5 (-232<=ZIM5<=300)
AF_I_MID6: ZIM6
ZIM6: infinity adjustment value of focus at zoom position
middle6 (-280<=ZIM6<=342)
AF_I_TELE: ZIT
ZIT: infinity adjustment value of focus at zoom position
tele (-230<=ZIT<=324)
QR_Z_WIDE: QRZW
QRZW: adjustment value of zoom written on QR code
(-102<=QRZW<=-75)
QR_F_I_WIDE: QRFW
QRFW: adjustment value of focus position wide written on
QR code (-63<=QRFW<=261)
3. Lens Adjustment (1m)
Adjustment location:
Focus of computer screen
Measuring location:
Computer screen
Measuring equipment:
Siemens star chart (A3)
Preparation:
Fluorescent light illumination with no flicker (incandescent
light cannot be used.)
Illumination above the subject should be 700 lux ± 10%.
Note:
Do not vibrate during the adjustment.
If readjusting after it has already been adjusted, wait for 15
minutes or more for the unit to cool down first.
Adjusting method:
1. It turns on power.
2. Set the siemens star chart 100 ± 1.0 cm from lens surface
so that it becomes center of the screen (zoom wide and
tele). Set the camera and the chart in a straight, and do
not put optical systems (mirror and conversion lens etc.)
3. Connect the camera’s USB terminal to the computer’
USB connector.
4. Double-click on the DscCalDi.exe.
5. Click the “Focus”, and Click the “Yes”.
6. Lens adjustment value will appear on the screen.
7. Click the OK.
Camera
200 cm
Siemens
star chart
DscCalDi
x
OK
Focus Result
AF_TEMP_AD: 445
AF_WIDE: 9
AF_MID1: 11
AF_MID2: 15
AF_MID3: 25
AF_MID4: 26
AF_MID5: 24
AF_MID6: 19
AF_TELE: 17
!
100 ± 1.0 cm
Dsc Calibration
x
OK
Infinity calibration :
AF_I_WIDE: 24
AF_I_MID1: 23
AF_I_MID2: 23
AF_I_MID3: 23
AF_I_MID4: 14
AF_I_MID5: 5
AF_I_MID6: -4
AF_I_TELE: -15
QR_Z_WIDE: -86
QR_F_I_WIDE: 131
QR_F_I_TELE: -304
QR_Z_AORI: -86
QR_F_I_AORI: 131
IRIS_GAIN: 94
IRIS_OFFSET: 14
Copy
Summary of Contents for VCC-HD5400
Page 68: ...PRIVACY MASKING CHART ...
Page 69: ...SIEMENS STAR CHART ...