– 5 –
2-3. ADJUSTMENT
2-3-1. Voltage Adjustment
Adjustment location:
VR301, VR302
Measuring location:
TP305, TP306
Measuring equipment:
Digital multi meter
Subject:
No designation
Adjusting method:
1. A connector CN302 is removed and voltage is adjusted.
2. Adjust with VR301 to 9.0 V .
3. Adjust with VR302 to 5.0 V .
4. A connector CN302 is connected and the value of voltage is
confirmed. (
±
5 %)
5. When a voltage changes, readjustment is done.
POWER board (Parts side)
TP306
TP302
TP301
TP303
TP305
TP304
TP307
VR301
CN301
CN302
VR302
IC301